Scatter Correction with Combined Single-Scatter Simulation and Monte Carlo Simulation Scaling Improved the Visual Artifacts and Quantification in 3-Dimensional Brain PET/CT Imaging with 15O-Gas Inhalation.

Keiichi Magota1, Tohru Shiga2, Yukari Asano1, Daiki Shinyama3, Jinghan Ye4, Amy E Perkins4, Piotr J Maniawski4, Takuya Toyonaga5, Kentaro Kobayashi5, Kenji Hirata5, Chietsugu Katoh6, Naoya Hattori5, Nagara Tamaki5.   

Abstract

In 3-dimensional PET/CT imaging of the brain with 15O-gas inhalation, high radioactivity in the face mask creates cold artifacts and affects the quantitative accuracy when scatter is corrected by conventional methods (e.g., single-scatter simulation [SSS] with tail-fitting scaling [TFS-SSS]). Here we examined the validity of a newly developed scatter-correction method that combines SSS with a scaling factor calculated by Monte Carlo simulation (MCS-SSS).
Methods: We performed phantom experiments and patient studies. In the phantom experiments, a plastic bottle simulating a face mask was attached to a cylindric phantom simulating the brain. The cylindric phantom was filled with 18F-FDG solution (3.8-7.0 kBq/mL). The bottle was filled with nonradioactive air or various levels of 18F-FDG (0-170 kBq/mL). Images were corrected either by TFS-SSS or MCS-SSS using the CT data of the bottle filled with nonradioactive air. We compared the image activity concentration in the cylindric phantom with the true activity concentration. We also performed 15O-gas brain PET based on the steady-state method on patients with cerebrovascular disease to obtain quantitative images of cerebral blood flow and oxygen metabolism.
Results: In the phantom experiments, a cold artifact was observed immediately next to the bottle on TFS-SSS images, where the image activity concentrations in the cylindric phantom were underestimated by 18%, 36%, and 70% at the bottle radioactivity levels of 2.4, 5.1, and 9.7 kBq/mL, respectively. At higher bottle radioactivity, the image activity concentrations in the cylindric phantom were greater than 98% underestimated. For the MCS-SSS, in contrast, the error was within 5% at each bottle radioactivity level, although the image generated slight high-activity artifacts around the bottle when the bottle contained significantly high radioactivity. In the patient imaging with 15O2 and C15O2 inhalation, cold artifacts were observed on TFS-SSS images, whereas no artifacts were observed on any of the MCS-SSS images.
Conclusion: MCS-SSS accurately corrected the scatters in 15O-gas brain PET when the 3-dimensional acquisition mode was used, preventing the generation of cold artifacts, which were observed immediately next to a face mask on TFS-SSS images. The MCS-SSS method will contribute to accurate quantitative assessments.
© 2017 by the Society of Nuclear Medicine and Molecular Imaging.

Entities:  

Keywords:  15O-gas brain PET; 3-dimensional PET; Monte Carlo simulation; scatter correction; scatter fraction

Mesh:

Substances:

Year:  2017        PMID: 28646012     DOI: 10.2967/jnumed.117.193060

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  2 in total

1.  Halo artifacts of indwelling urinary catheter by inaccurate scatter correction in 18F-FDG PET/CT imaging: incidence, mechanism, and solutions.

Authors:  Keiichi Magota; Naoto Numata; Daiki Shinyama; Junya Katahata; Yamato Munakata; Piotr J Maniawski; Kentaro Kobayashi; Osamu Manabe; Kenji Hirata; Ukihide Tateishi; Kohsuke Kudo; Tohru Shiga
Journal:  EJNMMI Phys       Date:  2020-11-13

Review 2.  Quantification of brain oxygen extraction and metabolism with [15O]-gas PET: A technical review in the era of PET/MRI.

Authors:  Audrey P Fan; Hongyu An; Farshad Moradi; Jarrett Rosenberg; Yosuke Ishii; Tadashi Nariai; Hidehiko Okazawa; Greg Zaharchuk
Journal:  Neuroimage       Date:  2020-07-04       Impact factor: 6.556

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.