Literature DB >> 28644804

Global Time-Delay Estimation in Ultrasound Elastography.

Hoda Sadat Hashemi, Hassan Rivaz.   

Abstract

A critical step in quasi-static ultrasound elastography is the estimation of time delay between two frames of radio-frequency (RF) data that are obtained while the tissue is undergoing deformation. This paper presents a novel technique for time-delay estimation (TDE) of all samples of RF data simultaneously, thereby exploiting all the information in RF data for TDE. A nonlinear cost function that incorporates similarity of RF data intensity and prior information of displacement continuity is formulated. Optimization of this function involves searching for TDE of all samples of the RF data, rendering the optimization intractable with conventional techniques given that the number of variables can be approximately one million. Therefore, the optimization problem is converted to a sparse linear system of equations, and is solved in real time using a computationally efficient optimization technique. We call our method GLobal Ultrasound Elastography (GLUE), and compare it to dynamic programming analytic minimization (DPAM) and normalized cross correlation (NCC) techniques. Our simulation results show that the contrast-to-noise ratio (CNR) values of the axial strain maps are 4.94 for NCC, 14.62 for DPAM, and 26.31 for GLUE. Our results on experimental data from tissue mimicking phantoms show that the CNR values of the axial strain maps are 1.07 for NCC, 16.01 for DPAM, and 18.21 for GLUE. Finally, our results on in vivo data show that the CNR values of the axial strain maps are 3.56 for DPAM and 13.20 for GLUE.

Entities:  

Mesh:

Year:  2017        PMID: 28644804     DOI: 10.1109/TUFFC.2017.2717933

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  10 in total

1.  Locally optimized correlation-guided Bayesian adaptive regularization for ultrasound strain imaging.

Authors:  Rashid Al Mukaddim; Nirvedh H Meshram; Tomy Varghese
Journal:  Phys Med Biol       Date:  2020-03-19       Impact factor: 3.609

2.  Improving Ultrasound Lateral Strain Estimation Accuracy using Log Compression of Regularized Correlation Function.

Authors:  Rashid Al Mukaddim; Tomy Varghese
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2020-07

3.  Neural-network-based Motion Tracking for Breast Ultrasound Strain Elastography: An Initial Assessment of Performance and Feasibility.

Authors:  Bo Peng; Yuhong Xian; Quan Zhang; Jingfeng Jiang
Journal:  Ultrason Imaging       Date:  2020-01-30       Impact factor: 1.578

4.  A data-driven approach to characterizing nonlinear elastic behavior of soft materials.

Authors:  Yiliang Wang; Jamshid Ghaboussi; Cameron Hoerig; Michael F Insana
Journal:  J Mech Behav Biomed Mater       Date:  2022-03-25

5.  Modeling Uncertainty of Strain Ratio Measurements in Ultrasound Breast Strain Elastography: A Factorial Experiment.

Authors:  David Rosen; Jingfeng Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-23       Impact factor: 2.725

6.  Analytic Global Regularized Backscatter Quantitative Ultrasound.

Authors:  Noushin Jafarpisheh; Timothy J Hall; Hassan Rivaz; Ivan M Rosado-Mendez
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-04-26       Impact factor: 2.725

7.  Evaluation of Three Different Approaches for Automated Time Delay Estimation for Distributed Sensor Systems of Electric Vehicles.

Authors:  Jakob Pfeiffer; Xuyi Wu; Ahmed Ayadi
Journal:  Sensors (Basel)       Date:  2020-01-08       Impact factor: 3.576

8.  Spatiotemporal Bayesian Regularization for Cardiac Strain Imaging: Simulation and In Vivo Results.

Authors:  Rashid Al Mukaddim; Nirvedh H Meshram; Ashley M Weichmann; Carol C Mitchell; Tomy Varghese
Journal:  IEEE Open J Ultrason Ferroelectr Freq Control       Date:  2021-11-22

9.  Main Uncertainties in the RF Ultrasound Scanning Simulation of the Standard Ultrasound Phantoms.

Authors:  Monika Makūnaitė; Rytis Jurkonis; Arūnas Lukoševičius; Mindaugas Baranauskas
Journal:  Sensors (Basel)       Date:  2021-06-28       Impact factor: 3.576

10.  Nonlocal Coherent Denoising of RF Data for Ultrasound Elastography.

Authors:  P Khavari; A Asif; M Boily; H Rivaz
Journal:  J Healthc Eng       Date:  2018-06-24       Impact factor: 2.682

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.