Literature DB >> 28643529

Correlation between adenoma detection rate and novel quality indicators for screening colonoscopy. A proposal for quality measures tool kit.

Mohamed M Abdelfatah1, Sherif Elhanafi2, Marc J Zuckerman3, Mohamed O Othman4.   

Abstract

BACKGROUND AND AIMS: Adenoma detection rate (ADR) is the most validated quality indicator for colonoscopy. Calculating ADR may not yield information in regards to advanced adenoma detection rate (advanced ADR). In addition, calculating ADR for individual endoscopists cannot distinguish between those who find only one versus more than one adenoma per colonoscopy. Several novel quality indictors were recently proposed to ensure adequate assessment of quality during colonoscopy. Our study aims to determine the correlation between ADR and novel quality indicators.
METHODS: A retrospective cohort study of patients undergoing screening colonoscopy in a university hospital setting. Patient characteristics and colonoscopy findings were combined and analyzed to calculate the correlation of ADR with novel quality indicators using Spearman's rank-order correlation were used.
RESULTS: A total of 1433 patients out of 2116 patients met the inclusion criteria. There was a significant positive correlation between ADR correlated with [advanced-ADR-2, nonadvanced-ADR, adenoma per colonoscopy, Multiplicity detection rate and ADR-Plus] r = (0.82, 0.99, 0.99, 0.07 and 0.85), respectively. However, ADR did not correlate with advanced-ADR and adenomas per positive participant.
CONCLUSION: Adding advanced-ADR and adenomas per positive participant to ADR may create a more comprehensive quality indicators tool kit, which is sensitive and difficult to game. Future studies are needed to investigate the impact of the tool kit on the interval cancers and adenoma missing rate.

Entities:  

Keywords:  Adenoma; colonoscopy; colorectal neoplasms; early detection of cancer

Mesh:

Year:  2017        PMID: 28643529     DOI: 10.1080/00365521.2017.1339827

Source DB:  PubMed          Journal:  Scand J Gastroenterol        ISSN: 0036-5521            Impact factor:   2.423


  2 in total

Review 1.  Challenges Facing the Detection of Colonic Polyps: What Can Deep Learning Do?

Authors:  Samy A Azer
Journal:  Medicina (Kaunas)       Date:  2019-08-12       Impact factor: 2.430

2.  Systematic analysis of the test design and performance of AI/ML-based medical devices approved for triage/detection/diagnosis in the USA and Japan.

Authors:  Mitsuru Yuba; Kiyotaka Iwasaki
Journal:  Sci Rep       Date:  2022-10-07       Impact factor: 4.996

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.