Literature DB >> 28639728

Prospective use of Ablation Index targets improves clinical outcomes following ablation for atrial fibrillation.

Ahmed Hussein1, Moloy Das2, Vivek Chaturvedi1, Issa Khalil Asfour1, Niji Daryanani1, Maureen Morgan1, Christina Ronayne1, Matthew Shaw1, Richard Snowdon1, Dhiraj Gupta1.   

Abstract

AIMS: Late recovery of ablated tissue leading to reconnection of pulmonary veins remains common following radiofrequency catheter ablation for AF. Ablation Index (AI), a novel ablation quality marker, incorporates contact force (CF), time, and power in a weighted formula. We hypothesized that prospective use of our previously published derived AI targets would result in better outcomes when compared to CF-guided ablation.
METHODS: Eighty-nine consecutive drug-refractory AF patients (49% paroxysmal) underwent AI-guided ablation (AI-group). AI targets were 550 for anterior/roof and 400 for posterior/inferior left atrial segments. Procedural and clinical outcomes of these patients were compared to 89 propensity-matched controls who underwent CF-guided ablation (CF-group). All 178 procedures were otherwise similar, and both groups were followed-up for 12 months. The last 25 patients from each group underwent analysis of all VisiTags™ for ablation duration, CF, Force-Time Integral, and impedance drop.
RESULTS: First-pass pulmonary vein isolation (PVI) was more frequent in AI-group than in CF-group (173 [97%] vs. 149 [84%] circles, P < 0.001), and acute PV reconnection was lower (11 [6%] vs. 24 [13%] circles, P = 0.02). Mean PVI ablation time was similar (AI-group: 42 ± 9 vs. CF-group: 45 ± 14 minutes, P = 0.14). Median impedance drop for AI-group was significantly higher than in CF-group (13.7 [9-19] Ω vs. 8.8 [5.2-13] Ω, P < 0.001). Two major complications occurred in CF-group and none in AI-group. Atrial tachyarrhythmia recurrence was significantly lower in AI-group (15 of 89 [17%]) than in CF-group (33 of 89 [37%], P = 0.002).
CONCLUSION: AI-guided ablation is associated with significant improvements in the incidence of acute PV reconnection and atrial tachyarrhythmia recurrence rate compared to CF-guided ablation, potentially due to creation of better quality lesions as suggested by greater impedance drop.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  ablation index; atrial fibrillation; contact force; impedance drop; pulmonary vein isolation

Mesh:

Year:  2017        PMID: 28639728     DOI: 10.1111/jce.13281

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  33 in total

1.  Lesion index: a novel guide in the path of successful pulmonary vein isolation.

Authors:  Antonio Dello Russo; Gaetano M Fassini; Michela Casella; Elena Romanelli; Salvatore Pala; Stefania Riva; Valentina Catto; Massimo Moltrasio; Fabrizio Tundo; Martina Zucchetti; Benedetta Majocchi; Maria Antonietta Dessanai; Francesca Pizzamiglio; Giulia Vettor; Valentina Ribatti; Alessio Gasperetti; Selene Cellucci; Gabriele Negro; Rita Sicuso; Corrado Carbucicchio; Claudio Tondo
Journal:  J Interv Card Electrophysiol       Date:  2018-12-04       Impact factor: 1.900

Review 2.  3D Mapping for PVI- Geometry, Image Integration and Incorporation of Contact Force Into Work Flow.

Authors:  Martin Borlich; Leon Iden; Krister Kuhnhardt; Ingo Paetsch; Gerhard Hindricks; Philipp Sommer
Journal:  J Atr Fibrillation       Date:  2018-04-30

3.  Left atrial anterior line ablation using ablation index and inter-lesion distance measurement.

Authors:  Francesco Santoro; Andreas Metzner; Natale Daniele Brunetti; Christian-H Heeger; Shibu Mathew; Bruno Reissmann; Christine Lemeš; Tilman Maurer; Thomas Fink; Laura Rottner; Osamu Inaba; Karl-Heinz Kuck; Feifan Ouyang; Andreas Rillig
Journal:  Clin Res Cardiol       Date:  2019-02-02       Impact factor: 5.460

4.  Lesion modeling, characterization, and visualization for image-guided cardiac ablation therapy monitoring.

Authors:  Cristian A Linte; Jon J Camp; Maryam E Rettmann; Dieter Haemmerich; Mehmet K Aktas; David T Huang; Douglas L Packer; David R Holmes
Journal:  J Med Imaging (Bellingham)       Date:  2018-03-01

5.  An ablation index operator-independent approach to improve efficacy in atrial fibrillation ablation at 24-month follow-up: a single center experience.

Authors:  Michela Casella; Antonio Dello Russo; Stefania Riva; Valentina Catto; Gabriele Negro; Rita Sicuso; Selene Cellucci; Alessio Gasperetti; Martina Zucchetti; Valentina Ribatti; Viviana Biagioli; Gaetano Fassini; Luigi Di Biase; Andrea Natale; Claudio Tondo
Journal:  J Interv Card Electrophysiol       Date:  2019-07-16       Impact factor: 1.900

6.  Pulmonary vein isolation using Ablation Index improves outcome in patients with atrial fibrillation.

Authors:  Jonas Elmer Pedersen; Kim Frost Lauritsen; Jens Brock Johansen; Niels Christian Foldager Sandgaard; Jorgen Dalhoj; Stig Djurhuus; Jacob Pontoppidan
Journal:  J Atr Fibrillation       Date:  2020-04-30

7.  Rationale and study design for ablation of paroxysmal atrial fibrillation guided by ablation index: a multi-center, prospective randomized trial (PAF-AI trial).

Authors:  Ruhong Jiang; Minglong Chen; Jie Fan; Fu Yi; Anli Tang; Xingpeng Liu; Wenqing Zhu; Shaowen Liu; Xiaobo Huang; Weizhu Ju; Xi Zhang; Jie Li; Jiangui He; Liang Shi; Genqing Zhou; Yuegang Wang; Chenyang Jiang
Journal:  J Interv Card Electrophysiol       Date:  2020-05-11       Impact factor: 1.900

8.  Gains in Paroxysmal Atrial Fibrillation Ablation Using a Standardized Workflow to Optimize Contact Force Technologies.

Authors:  Jose Osorio; Tina D Hunter; Rosemary S Bubien; Anil Rajendra; Joaquin Arciniegas; Gustavo Morales
Journal:  J Atr Fibrillation       Date:  2018-12-31

9.  Radiofrequency Versus Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: Durability of Pulmonary Vein Isolation and Effect on Atrial Fibrillation Burden: The RACE-AF Randomized Controlled Trial.

Authors:  Samuel K Sørensen; Arne Johannessen; René Worck; Morten L Hansen; Jim Hansen
Journal:  Circ Arrhythm Electrophysiol       Date:  2021-04-09

10.  Very high-power short-duration temperature-controlled ablation versus conventional power-controlled ablation for pulmonary vein isolation: The fast and furious - AF study.

Authors:  Roland Richard Tilz; Makoto Sano; Julia Vogler; Thomas Fink; Roza Saraei; Vanessa Sciacca; Bettina Kirstein; Huong-Lan Phan; Sascha Hatahet; Lisbeth Delgado Lopez; Anna Traub; Charlotte Eitel; Michael Schlüter; Karl-Heinz Kuck; Christian-Hendrik Heeger
Journal:  Int J Cardiol Heart Vasc       Date:  2021-07-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.