Literature DB >> 28639425

High-resolution anorectal manometry: A comparison of solid-state and water-perfused catheters.

A M P Rasijeff1,2, M Withers1, J M Burke1, W Jackson1, S M Scott2.   

Abstract

BACKGROUND: Anorectal manometry is the most commonly performed investigation for assessment of anorectal dysfunction. Findings from previous studies comparing water-perfused (WP) and solid-state (SS) techniques in the anorectum are conflicting. We compared anal sphincter pressure at rest and during dynamic maneuvers (squeezing and coughing) in healthy volunteers using SS and WP high-resolution anorectal manometry (HR-ARM) employing equivalent catheter configurations, a standardized protocol, and identical data acquisition and analysis software.
METHODS: Sixty healthy volunteers (40F; median age: 40; range: 18-74) underwent WP and SS HR-ARM in randomized order. Anal resting pressure, and squeeze and cough increments were measured. Median pressure and 5th and 95th percentiles were calculated for each maneuver and compared using Wilcoxon signed-rank test. Bland and Altman plots were used to assess agreement between the systems. The impact of gender and parity was also explored. KEY
RESULTS: Anal sphincter pressure measurements during squeeze (P<.001) and cough (P<.001) were significantly higher using SS HR-ARM than WP HR-ARM. No differences were seen at rest between the two types of catheter (nulliparous: P=.304; parous: P=.390; males: P=.167). Normal ranges for SS and WP manometry from this small group of healthy volunteers are presented. CONCLUSIONS & INFERENCES: Greater sensitivity to rapid pressure change is one of the advantages associated with SS HR-ARM. This is reflected in the differences observed during dynamic maneuvers performed during this study. Catheter type should be taken into consideration when selecting normal ranges for comparison to disease states.
© 2017 John Wiley & Sons Ltd.

Entities:  

Keywords:  Healthy volunteers; Manometry; Normative data; Solid-state; Water-perfused

Mesh:

Year:  2017        PMID: 28639425     DOI: 10.1111/nmo.13124

Source DB:  PubMed          Journal:  Neurogastroenterol Motil        ISSN: 1350-1925            Impact factor:   3.598


  7 in total

Review 1.  High-Resolution Anorectal Manometry - New Insights in the Diagnostic Assessment of Functional Anorectal Disorders.

Authors:  Henriette Heinrich; Benjamin Misselwitz
Journal:  Visc Med       Date:  2018-04-20

Review 2.  Review of the indications, methods, and clinical utility of anorectal manometry and the rectal balloon expulsion test.

Authors:  Adil E Bharucha; Guido Basilisco; Allison Malcolm; Tae Hee Lee; Matthew B Hoy; S Mark Scott; Satish S C Rao
Journal:  Neurogastroenterol Motil       Date:  2022-02-27       Impact factor: 3.960

Review 3.  High-resolution colonic manometry and its clinical application in patients with colonic dysmotility: A review.

Authors:  Yu-Wei Li; Yong-Jun Yu; Fei Fei; Min-Ying Zheng; Shi-Wu Zhang
Journal:  World J Clin Cases       Date:  2019-09-26       Impact factor: 1.337

4.  Sleep Deficiency Is Associated With Exacerbation of Symptoms and Impairment of Anorectal and Autonomic Functions in Patients With Functional Constipation.

Authors:  Jie Liu; Wei Wang; Jiashuang Tian; Chaolan Lv; Yuhan Fu; Ronnie Fass; Gengqing Song; Yue Yu
Journal:  Front Neurosci       Date:  2022-07-07       Impact factor: 5.152

5.  Evaluation of 153 Asymptomatic Subjects Using the Anopress Portable Anal Manometry Device.

Authors:  Cosimo Alex Leo; Emanuel Cavazzoni; Gregory P Thomas; Jonathan Hodgkison; Jamie Murphy; Carolynne J Vaizey
Journal:  J Neurogastroenterol Motil       Date:  2018-07-30       Impact factor: 4.924

Review 6.  The London Classification: Improving Characterization and Classification of Anorectal Function with Anorectal Manometry.

Authors:  S Mark Scott; Emma V Carrington
Journal:  Curr Gastroenterol Rep       Date:  2020-09-15

7.  Evaluation of Anorectal Function in Perianal Crohn's Disease: A Pilot Study.

Authors:  Andreia Albuquerque; John Casey; Grace Fairlamb; Lesley A Houghton; Christian Selinger
Journal:  J Clin Med       Date:  2021-12-16       Impact factor: 4.241

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.