Motion estimation for cardiac functional analysis using two x-ray computed tomography scans.

George S K Fung1, Luisa Ciuffo2, Hiroshi Ashikaga2,3, Katsuyuki Taguchi1.   

Abstract

PURPOSE: This work concerns computed tomography (CT)-based cardiac functional analysis (CFA) with a reduced radiation dose. As CT-CFA requires images over the entire heartbeat, the scans are often performed at 10-20% of the tube current settings that are typically used for coronary CT angiography. A large image noise then degrades the accuracy of motion estimation. Moreover, even if the scan was performed during the sinus rhythm, the cardiac motion observed in CT images may not be cyclic with patients with atrial fibrillation. In this study, we propose to use two CT scan data, one for CT angiography at a quiescent phase at a standard dose and the other for CFA over the entire heart beat at a lower dose.
METHODS: We have made the following four modifications to an image-based cardiac motion estimation method we have previously developed for a full-dose retrospectively gated coronary CT angiography: (a) a full-dose prospectively gated coronary CT angiography image acquired at the least motion phase was used as the reference image; (b) a three-dimensional median filter was applied to lower-dose retrospectively gated cardiac images acquired at 20 phases over one heartbeat in order to reduce image noise; (c) the strength of the temporal regularization term was made adaptive; and (d) a one-dimensional temporal filter was applied to the estimated motion vector field in order to decrease jaggy motion patterns. We describe the conventional method iME1 and the proposed method iME2 in this article. Five observers assessed the accuracy of the estimated motion vector field of iME2 and iME1 using a 4-point scale. The observers repeated the assessment with data presented in a new random order 1 week after the first assessment session.
RESULTS: The study confirmed that the proposed iME2 was robust against the mismatch of noise levels, contrast enhancement levels, and shapes of the chambers. There was a statistically significant difference between iME2 and iME1 (accuracy score, 2.08 ± 0.81 versus 2.77 ± 0.98, P < 0.01) and the improvement by the score of + 0.69 seemed clinically relevant. Inter-observer concordance was good: The inter-class correlation coefficient was 0.63 and Kendall's rank correlation coefficients were in the range of 0.41-0.67 (P < 0.01), respectively. Intra-observer reproducibility between sessions was good with the inter-class correlation coefficient of 0.76.
CONCLUSION: We have proposed iME2 method for CT-CFA with two CT scans. The observer study verified the robustness and accuracy of iME2 method and its improved performance over iME1 method.
© 2017 American Association of Physicists in Medicine.

Entities:  

Keywords:  cardiac; cardiac functional analysis; computed tomography; motion estimation

Mesh:

Year:  2017        PMID: 28639400      PMCID: PMC5603222          DOI: 10.1002/mp.12425

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Respiratory motion estimation from slowly rotating x-ray projections: theory and simulation.

Authors:  Rongping Zeng; Jeffrey A Fessler; James M Balter
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

2.  A simple fixed-point approach to invert a deformation field.

Authors:  Mingli Chen; Weiguo Lu; Quan Chen; Kenneth J Ruchala; Gustavo H Olivera
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

3.  Registration of 4D time-series of cardiac images with multichannel Diffeomorphic Demons.

Authors:  Jean-Marc Peyrat; Hervé Delingette; Maxime Sermesant; Xavier Pennec; Chenyang Xu; Nicholas Ayache
Journal:  Med Image Comput Comput Assist Interv       Date:  2008

4.  Quantitative assessment of atrial regional function using motion estimation computed tomography.

Authors:  Hiroshi Ashikaga; Jochen Cammin; Qiulin Tang; Karly Knudsen; Yuko Inoue; Elliot K Fishman; Katsuyuki Taguchi
Journal:  J Comput Assist Tomogr       Date:  2014 Sep-Oct       Impact factor: 1.826

5.  Coronary computed tomography and triple rule out CT in patients with acute chest pain and an intermediate cardiac risk profile. Part 1: impact on patient management.

Authors:  Joachim Gruettner; Christian Fink; Thomas Walter; Mathias Meyer; Paul Apfaltrer; U Joseph Schoepf; Joachim Saur; Tim Sueselbeck; Dominik Traunwieser; Richard Takx; Stefan Kralev; Martin Borggrefe; Stefan O Schoenberg; Thomas Henzler
Journal:  Eur J Radiol       Date:  2012-06-29       Impact factor: 3.528

6.  A new method for cardiac computed tomography regional function assessment: stretch quantifier for endocardial engraved zones (SQUEEZ).

Authors:  Amir Pourmorteza; Karl H Schuleri; Daniel A Herzka; Albert C Lardo; Elliot R McVeigh
Journal:  Circ Cardiovasc Imaging       Date:  2012-02-16       Impact factor: 7.792

7.  A fully four-dimensional, iterative motion estimation and compensation method for cardiac CT.

Authors:  Qiulin Tang; Jochen Cammin; Somesh Srivastava; Katsuyuki Taguchi
Journal:  Med Phys       Date:  2012-07       Impact factor: 4.071

8.  Coronary computed tomography and triple rule out CT in patients with acute chest pain and an intermediate cardiac risk for acute coronary syndrome: part 2: economic aspects.

Authors:  Thomas Henzler; Joachim Gruettner; Mathias Meyer; Baerbel Rothhaar; Paul Apfaltrer; Franz Metzger; Martin Borggrefe; U Joseph Schoepf; Stefan O Schoenberg; Christian Fink
Journal:  Eur J Radiol       Date:  2012-07-24       Impact factor: 3.528

9.  Regional function analysis of left atrial appendage using motion estimation CT and risk of stroke in patients with atrial fibrillation.

Authors:  Abdullah Al-Issa; Yuko Inoue; Jochen Cammin; Qiulin Tang; Saman Nazarian; Hugh Calkins; Elliot K Fishman; Katsuyuki Taguchi; Hiroshi Ashikaga
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-09-04       Impact factor: 6.875

  9 in total
  2 in total

1.  Iterative inversion of deformation vector fields with feedback control.

Authors:  Abhishek Dubey; Alexandros-Stavros Iliopoulos; Xiaobai Sun; Fang-Fang Yin; Lei Ren
Journal:  Med Phys       Date:  2018-06-10       Impact factor: 4.071

2.  Vectors through a cross-sectional image (VCI): A visualization method for four-dimensional motion analysis for cardiac computed tomography.

Authors:  Masafumi Kidoh; Daisuke Utsunomiya; Yoshinori Funama; Hiroshi Ashikaga; Takeshi Nakaura; Seitaro Oda; Hideaki Yuki; Kenichiro Hirata; Yuji Iyama; Yasunori Nagayama; Toshihiro Fukui; Yasuyuki Yamashita; Katsuyuki Taguchi
Journal:  J Cardiovasc Comput Tomogr       Date:  2017-09-23
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.