Literature DB >> 28636458

Contamination of firefighter personal protective equipment and skin and the effectiveness of decontamination procedures.

Kenneth W Fent1, Barbara Alexander2, Jennifer Roberts2, Shirley Robertson2, Christine Toennis2, Deborah Sammons2, Stephen Bertke1, Steve Kerber3, Denise Smith4,5, Gavin Horn5.   

Abstract

Firefighters' skin may be exposed to chemicals via permeation/penetration of combustion byproducts through or around personal protective equipment (PPE) or from the cross-transfer of contaminants on PPE to the skin. Additionally, volatile contaminants can evaporate from PPE following a response and be inhaled by firefighters. Using polycyclic aromatic hydrocarbons (PAHs) and volatile organic compounds (VOCs) as respective markers for non-volatile and volatile substances, we investigated the contamination of firefighters' turnout gear and skin following controlled residential fire responses. Participants were grouped into three crews of twelve firefighters. Each crew was deployed to a fire scenario (one per day, four total) and then paired up to complete six fireground job assignments. Wipe sampling of the exterior of the turnout gear was conducted pre- and post-fire. Wipe samples were also collected from a subset of the gear after field decontamination. VOCs off-gassing from gear were also measured pre-fire, post-fire, and post-decon. Wipe sampling of the firefighters' hands and neck was conducted pre- and post-fire. Additional wipes were collected after cleaning neck skin. PAH levels on turnout gear increased after each response and were greatest for gear worn by firefighters assigned to fire attack and to search and rescue activities. Field decontamination using dish soap, water, and scrubbing was able to reduce PAH contamination on turnout jackets by a median of 85%. Off-gassing VOC levels increased post-fire and then decreased 17-36 min later regardless of whether field decontamination was performed. Median post-fire PAH levels on the neck were near or below the limit of detection (< 24 micrograms per square meter [µg/m2]) for all positions. For firefighters assigned to attack, search, and outside ventilation, the 75th percentile values on the neck were 152, 71.7, and 39.3 µg/m2, respectively. Firefighters assigned to attack and search had higher post-fire median hand contamination (135 and 226 µg/m2, respectively) than other positions (< 10.5 µg/m2). Cleansing wipes were able to reduce PAH contamination on neck skin by a median of 54%.

Entities:  

Keywords:  Contaminants; PAHs; decontamination; evaporation; firefighters; turnout gear

Mesh:

Substances:

Year:  2017        PMID: 28636458     DOI: 10.1080/15459624.2017.1334904

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  37 in total

1.  Targeted GC-MS analysis of firefighters' exhaled breath: Exploring biomarker response at the individual level.

Authors:  M Ariel Geer Wallace; Joachim D Pleil; Karen D Oliver; Donald A Whitaker; Sibel Mentese; Kenneth W Fent; Gavin P Horn
Journal:  J Occup Environ Hyg       Date:  2019-04-01       Impact factor: 2.155

2.  Recovery and reactivity of polycyclic aromatic hydrocarbons collected on selected sorbent tubes and analyzed by thermal desorption-gas chromatography/mass spectrometry.

Authors:  M Ariel Geer Wallace; Joachim D Pleil; Donald A Whitaker; Karen D Oliver
Journal:  J Chromatogr A       Date:  2019-05-16       Impact factor: 4.759

3.  Calibration and performance of synchronous SIM/scan mode for simultaneous targeted and discovery (non-targeted) analysis of exhaled breath samples from firefighters.

Authors:  M Ariel Geer Wallace; Joachim D Pleil; Sibel Mentese; Karen D Oliver; Donald A Whitaker; Kenneth W Fent
Journal:  J Chromatogr A       Date:  2017-07-28       Impact factor: 4.759

4.  Perceptions of Work-Related Health and Cancer Risks Among Women Firefighters: A Qualitative Study.

Authors:  Natasha Schaefer Solle; Katerina M Santiago; Paola Louzado Feliciano; Miriam M Calkins; Kenny Fent; Sara Jahnke; Natasha Parks; Heather Buren; Casey Grant; Jefferey L Burgess; Alberto J Caban-Martinez
Journal:  J Occup Environ Med       Date:  2021-12-01       Impact factor: 2.306

5.  Development of Fireground Exposure Simulator (FES) Prop for PPE Testing and Evaluation.

Authors:  Gavin P Horn; Steve Kerber; Jeffery Lattz; Richard M Kesler; Denise L Smith; Alex Mayer; Kenneth W Fent
Journal:  Fire Technol       Date:  2020-04-24       Impact factor: 3.605

6.  Management of Firefighters' Chemical & Cardiovascular Exposure Risks on the Fireground.

Authors:  Gavin P Horn; Steve Kerber; Kenneth W Fent; Denise L Smith
Journal:  Int Fire Serv J Leadersh Manag       Date:  2020

7.  Impact of Repeated Exposure and Cleaning on Protective Properties of Structural Firefighting Turnout Gear.

Authors:  Gavin P Horn; Steve Kerber; Jessica Andrews; Richard M Kesler; Hannah Newman; Jacob W Stewart; Kenneth W Fent; Denise L Smith
Journal:  Fire Technol       Date:  2021       Impact factor: 3.605

8.  Pilot study on the efficiency of water-only decontamination for firefighters' turnout gear.

Authors:  Anthony Calvillo; Erin Haynes; Jeff Burkle; Kenny Schroeder; Angelo Calvillo; Julie Reese; Tiina Reponen
Journal:  J Occup Environ Hyg       Date:  2019-01-31       Impact factor: 2.155

9.  Non-targeted GC/MS analysis of exhaled breath samples: Exploring human biomarkers of exogenous exposure and endogenous response from professional firefighting activity.

Authors:  M Ariel Geer Wallace; Joachim D Pleil; Karen D Oliver; Donald A Whitaker; Sibel Mentese; Kenneth W Fent; Gavin P Horn
Journal:  J Toxicol Environ Health A       Date:  2019-03-23

10.  Effects of firefighting hood design, laundering and doffing on smoke protection, heat stress and wearability.

Authors:  Richard M Kesler; Alex Mayer; Kenneth W Fent; I-Chen Chen; A Shawn Deaton; R Bryan Ormond; Denise L Smith; Andrea Wilkinson; Steve Kerber; Gavin P Horn
Journal:  Ergonomics       Date:  2021-02-01       Impact factor: 2.561

View more