The presence of multiple or diffuse lesions on imaging is a contraindication to surgery for patients with intractable epilepsy. Theoretically, as a functional imaging technique, electrical impedance tomography (EIT) can accurately image epileptic foci. However, most current studies are limited to examining epileptic spikes and few studies use EIT for real-time imaging of seizure activity. Moreover, little is known about changes in electrical impedance during seizures. In this study, we used EIT to monitor seizure progression in real time and analyzed changes in electrical impedance during seizures. EIT and electroencephalography data were recorded simultaneously in rats. Sixty-three seizures were recorded from the cortices of eight rats. During 54 seizures, the average impedance decreased by between 4.86 and 9.17% compared with the baseline. Compared with the control group, the average impedance of the experimental group decreased significantly (P=0.004). Our results indicate that EIT can be used to detect and image electrical impedance reduction within lesions during epileptic seizures.Entities:
Mesh:
Year: 2017 PMID: 28628556 PMCID: PMC5491225 DOI: 10.1097/WNR.0000000000000823
Source DB: PubMed Journal: Neuroreport ISSN: 0959-4965 Impact factor: 1.837
Fig. 1Electrode positions for electrical impedance tomography (EIT) and electroencephalography (EEG) imaging. EIT and EEG electrodes are in the dashed box and the nondashed box, respectively.
Impedance changes detected by electrical impedance tomography in the experimental group
Fig. 2(a) Average resistivity value and reconstructed impedance changes in an experimental rat (no. 2). Plots of the average resistivity value against time (top). Seizure onset and offset are marked by vertical solid lines. Reconstructed impedance changes during ictal activity (middle). At the middle right, image orientation is indicated in the diagram with the directions, anterior (A), left (L), posterior (P), and right (R). The spectral bar on the right represents resistivity states and associated colors, from decreased resistivity (red) to normal baseline intensity (green) to increased resistivity (blue). The numbers, 0.5 and −0.5, are the upper and lower limits of the resistivity values, respectively. Simultaneously recorded EEG segment during the ictal period from Fp1 and Fp2 electrodes (bottom). (b) Reconstruction of impedance changes in a control rat (no. 5; top) and plots of the corresponding average resistivity value against time (bottom).
Fig. 3Tomographic images of impedance changes showing the onset and progression of seizure activity in eight rats.