Manamu Nagakura1, Yasuhiro Tanimoto2, Norihiro Nishiyama1. 1. Department of Dental Biomaterials, Nihon University School of Dentistry at Matsudo, 2-870-1 Sakaecho Nishi, Matsudo, Chiba 271-8587, Japan. 2. Department of Dental Biomaterials, Nihon University School of Dentistry at Matsudo, 2-870-1 Sakaecho Nishi, Matsudo, Chiba 271-8587, Japan. Electronic address: tanimoto.yasuhiro@nihon-u.ac.jp.
Abstract
PURPOSE: The purpose of this study was to investigate the color stability of a glass-fiber-reinforced thermoplastic (GFRTP), for use in non-metal clasp dentures (NMCDs). METHODS: GFRTPs composed of E-glass fibers and polypropylene with 2 mass% of pigments were fabricated using injection molding. According to our previous study on the optimum fiber content for GFRTPs, we prepared GFRTPs with fiber contents of 0, 10, and 20 mass% (GF0, GF10, and GF20). Commercially available NMCD and PMMA materials were used as controls. The color changes of GFRTPs at 24h, and at 1, 2, and 4 weeks of coffee immersion at 37°C were measured by colorimetry, using the Commission Internationale de l'Eclairage (CIE) Lab system. The color stabilities of the GFRTPs were evaluated in two units: the color difference (ΔE∗) and National Bureau of Standards (NBS) units. RESULTS: After immersion, none of the GFRTPs showed visible color change. From the colorimetry measurement using the CIE Lab system, the ΔE∗ values of the GFRTPs were 0.65-2.45. The NBS values of the GFRTPs were 0.60-2.25, all lower than the threshold level of 3.0, demonstrating clinically acceptable color changes. On the other hand, an available polyamide-based NMCD material exhibited "appreciable" color change, as measured in NBS units. CONCLUSIONS: The results indicate that the GFRTPs showed clinically acceptable color stability and might be satisfactory for clinical use. Therefore, GFRTPs are expected to become attractive materials for esthetic dentures.
PURPOSE: The purpose of this study was to investigate the color stability of a glass-fiber-reinforced thermoplastic (GFRTP), for use in non-metal clasp dentures (NMCDs). METHODS: GFRTPs composed of E-glass fibers and polypropylene with 2 mass% of pigments were fabricated using injection molding. According to our previous study on the optimum fiber content for GFRTPs, we prepared GFRTPs with fiber contents of 0, 10, and 20 mass% (GF0, GF10, and GF20). Commercially available NMCD and PMMA materials were used as controls. The color changes of GFRTPs at 24h, and at 1, 2, and 4 weeks of coffee immersion at 37°C were measured by colorimetry, using the Commission Internationale de l'Eclairage (CIE) Lab system. The color stabilities of the GFRTPs were evaluated in two units: the color difference (ΔE∗) and National Bureau of Standards (NBS) units. RESULTS: After immersion, none of the GFRTPs showed visible color change. From the colorimetry measurement using the CIE Lab system, the ΔE∗ values of the GFRTPs were 0.65-2.45. The NBS values of the GFRTPs were 0.60-2.25, all lower than the threshold level of 3.0, demonstrating clinically acceptable color changes. On the other hand, an available polyamide-based NMCD material exhibited "appreciable" color change, as measured in NBS units. CONCLUSIONS: The results indicate that the GFRTPs showed clinically acceptable color stability and might be satisfactory for clinical use. Therefore, GFRTPs are expected to become attractive materials for esthetic dentures.