Literature DB >> 28625444

Nitrous oxide for labor analgesia: Utilization and predictors of conversion to neuraxial analgesia.

Caitlin D Sutton1, Alexander J Butwick1, Edward T Riley1, Brendan Carvalho2.   

Abstract

STUDY
OBJECTIVE: We examined the characteristics of women who choose nitrous oxide for labor analgesia and identified factors that predict conversion from nitrous oxide to labor neuraxial analgesia.
DESIGN: Retrospective descriptive study.
SETTING: Labor and Delivery Ward. PATIENTS: 146 pregnant women who used nitrous oxide for analgesia during labor and delivery between September 2014 and September 2015.
INTERVENTIONS: Chart review only. MEASUREMENTS: Demographic, obstetric, and intrapartum characteristics of women using nitrous oxide were examined. Multivariable logistic regression was performed to identify factors associated with conversion from nitrous oxide to neuraxial analgesia. Data are presented as n (%), median [IQR], adjusted relative risk (aRR), and 95% confidence intervals (CI) as appropriate.
RESULTS: During the study period, 146 women used nitrous oxide for labor analgesia (accounting for 3% of the total deliveries). The majority (71.9%) of women who used nitrous oxide were nulliparous, and over half (51.9%) had expressed an initial preference for "nonmedical birth." The conversion rate to neuraxial blockade was 63.2%, compared to a concurrent institutional rate of 85.1% in women who did not use nitrous oxide. Factors associated with conversion from nitrous oxide to neuraxial blockade were labor induction (aRR=2.0, CI 1.2-3.3) and labor augmentation (aRR=1.7, CI 1.0-2.9).
CONCLUSION: Only a small number of women opted to use nitrous oxide during labor, analgesia was minimal, and most converted to neuraxial analgesia. Women with induced and augmented labors should be counseled about the increased likelihood that they will convert to neuraxial analgesia.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Labor analgesia; Nitrous oxide

Mesh:

Substances:

Year:  2017        PMID: 28625444     DOI: 10.1016/j.jclinane.2017.04.005

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  2 in total

1.  Caesarean delivery rates and analgesia effectiveness following injections of sterile water for back pain in labour: A multicentre, randomised placebo controlled trial.

Authors:  Nigel Lee; Yu Gao; Sally L Collins; Lena B Mårtensson; Wendy Randall; Toni-Marie Rowe; Sue Kildea
Journal:  EClinicalMedicine       Date:  2020-07-03

Review 2.  Update on Non-neuraxial Labor Analgesia.

Authors:  Dana Karol; Carolyn F Weiniger
Journal:  Curr Anesthesiol Rep       Date:  2021-08-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.