Literature DB >> 28624825

Intraoperative Real-Time Assessment of Liver Function with Near-Infrared Fluorescence Imaging.

Hajime Narasaki1, Takehiro Noji, Hideyuki Wada, Yuma Ebihara, Takahiro Tsuchikawa, Keisuke Okamura, Eiichi Tanaka, Toshiaki Shichinohe, Satoshi Hirano.   

Abstract

BACKGROUND: Postoperative liver failure is a serious complication after major hepatectomy, and perioperative prediction of its incidence using current technology is still very difficult. Near-infrared (NIR) fluorescence imaging allows quantitative assessment of the fluorescent signal from indocyanine green (ICG) in regions of interest on the liver surface. This method might offer a new promising modality for evaluating regional liver reserve. However, data are lacking regarding the relationship between liver function and fluorescent signals on the liver surface after intravenous ICG injection. This study was conducted to obtain the data necessary to apply NIR fluorescence imaging as a modality for measuring liver function.
MATERIALS AND METHODS: This study included 16 patients who underwent open hepatopancreatobiliary surgery between March 2011 and March 2012. After laparotomy, ICG was injected intravenously at 2.5 mg/L of liver volume, then the fluorescence intensity (FI) and signal-to-background ratio (SBR) in the lateral segment of the liver were assessed for 15 min. Intraoperative blood samples were also obtained to measure the plasma clearance rate of ICG (ICGK). Correlations between ICGK, liver volume, and SBR, as well as between ICGK, liver volume, and rate of change of FI were analyzed.
RESULTS: The experimental procedure was performed in all 16 patients. The FI of the liver increased rapidly after ICG injection, then became more gradual, reaching a near-plateau after 15 min. A significant correlation was seen between ICGK and the rate of change of FI up to 15 min (|rS| = 0.5725, p < 0.05).
CONCLUSION: This is the first report to show a relationship between liver function and fluorescent signals on the liver surface after intravenous ICG injection. Intraoperative NIR fluorescence imaging with ICG may be useful as a new method for assessing liver function.
© 2017 S. Karger AG, Basel.

Entities:  

Keywords:  Fluorescence imaging; Hepatectomy; Hepatic functional reserve; Indocyanine green; Liver function; Near-infrared fluorescence

Mesh:

Substances:

Year:  2017        PMID: 28624825     DOI: 10.1159/000477347

Source DB:  PubMed          Journal:  Eur Surg Res        ISSN: 0014-312X            Impact factor:   1.745


  4 in total

1.  Hepatic function assessment to predict post-hepatectomy liver failure: what can we trust? A systematic review.

Authors:  Federico Tomassini; Mariano C Giglio; Giuseppe De Simone; Roberto Montalti; Roberto I Troisi
Journal:  Updates Surg       Date:  2020-08-04

Review 2.  Fluorescence-guided hepatobiliary surgery with long and short wavelength fluorophores.

Authors:  Thinzar M Lwin; Robert M Hoffman; Michael Bouvet
Journal:  Hepatobiliary Surg Nutr       Date:  2020-10       Impact factor: 7.293

3.  Near-infrared fluorescence laparoscopy of the ureter with three preclinical dyes in a pig model.

Authors:  Jacqueline van den Bos; Mahdi Al-Taher; Nicole D Bouvy; Laurents P S Stassen
Journal:  Surg Endosc       Date:  2018-11-26       Impact factor: 4.584

4.  Near-infrared fluorescence imaging with indocyanine green for assessment of donor livers in a rat model of ischemia-reperfusion.

Authors:  Liyu Shan; Huan Chen; Lifei Yang; Zhe Feng; Yue Wang; Rongfeng Wang; Nana Zhang; Rongqian Wu; Yi Lv; Tao Ma
Journal:  BMC Gastroenterol       Date:  2022-01-20       Impact factor: 3.067

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.