Literature DB >> 28624620

AgBr nanoparticles/3D nitrogen-doped graphene hydrogel for fabricating all-solid-state luminol-electrochemiluminescence Escherichia coli aptasensors.

Nan Hao1, Xuan Zhang1, Zhou Zhou1, Rong Hua1, Ying Zhang1, Qian Liu1, Jing Qian1, Henan Li1, Kun Wang2.   

Abstract

It is necessary to develop rapid, simple and accurate detection method for Escherichia coli (E. coli) due to its widely distributed pathogenic bacteria. Herein, we prepared AgBr nanoparticles (NPs) anchored 3D nitrogen-doped graphene hydrogel (3DNGH) nanocomposites with an exceptionally large accessible surface by a simple hydrothermal approach. The as-prepared 3DNGH porous nanocomposite not only showed better conductivity than that of 3D graphene due to introducing nitrogen element into graphene framework, but also provided a high loading volume for immobilizing luminol. Meanwhile the anchored AgBr NPs served as the catalyst can effectively enhance the ECL behavior of luminol. And the resulting luminol/AgBr/3DNGH exhibited more excellent ECL performances, which was about 2, 3, 8 times enhanced respectively, comparing to luminol/AgBr/3DGH, luminol/3DNGH and luminol/AgBr/2DNG. Further, the multifunctional nanoarchitecture was used as the all-solid-state ECL platform for fabricating Escherichia coli aptasensors via glutaraldehyde as crosslinking agent between amine-functionalized E. coli aptamer and luminol/AgBr/3DNGH. Based on the steric hindrance mechanism that E.coli can significantly decrease the ECL intensity, the proposed aptasensor displayed a linear response for E.coli in the range from 0.5 to 500 cfu/mL with an extremely low detection limit of 0.17 cfu/mL (S/N). In addition, this ECL aptasensor possessed great advantages including the simple operation process, low-cost and sensitivity, which provided a promising approach for the E.coli detection in biomedical, food detection and environmental analysis.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptasensor; Electrochemiluminescence; Escherichia coli; Luminol; Nitrogen-doped graphene hydrogel

Mesh:

Substances:

Year:  2017        PMID: 28624620     DOI: 10.1016/j.bios.2017.06.025

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  12 in total

Review 1.  Electrochemical Biosensors in Food Safety: Challenges and Perspectives.

Authors:  Antonella Curulli
Journal:  Molecules       Date:  2021-05-15       Impact factor: 4.411

2.  pH-dependent nanodiamonds enhance the mechanical properties of 3D-printed hyaluronic acid nanocomposite hydrogels.

Authors:  Dae Gon Lim; Eunah Kang; Seong Hoon Jeong
Journal:  J Nanobiotechnology       Date:  2020-06-10       Impact factor: 10.435

3.  Electrochemiluminescence Detection of Sunset Yellow by Graphene Quantum Dots.

Authors:  Huimin Niu; Xin Yang; Yilei Wang; Mingchen Li; Guangliang Zhang; Peng Pan; Yangyang Qi; Zhengchun Yang; John Wang; Zhenyu Liao
Journal:  Front Chem       Date:  2020-06-30       Impact factor: 5.221

Review 4.  Recent Advances in Electrochemiluminescence Sensors for Pathogenic Bacteria Detection.

Authors:  Jinjin Shen; Ting Zhou; Ru Huang
Journal:  Micromachines (Basel)       Date:  2019-08-13       Impact factor: 2.891

Review 5.  Recent Progress in the Identification of Aptamers Against Bacterial Origins and Their Diagnostic Applications.

Authors:  Nevina E Trunzo; Ka Lok Hong
Journal:  Int J Mol Sci       Date:  2020-07-18       Impact factor: 5.923

Review 6.  Nanomaterial application in bio/sensors for the detection of infectious diseases.

Authors:  Elham Sheikhzadeh; Valerio Beni; Mohammed Zourob
Journal:  Talanta       Date:  2020-12-17       Impact factor: 6.057

Review 7.  Self-luminescent photodynamic therapy and pathogen detection for infectious diseases.

Authors:  Endong Zhang; Yiming Huang; Shu Wang
Journal:  Drug Deliv Transl Res       Date:  2021-05-06       Impact factor: 5.671

Review 8.  Application of Biosensors for Detection of Pathogenic Food Bacteria: A Review.

Authors:  Athmar A Ali; Ammar B Altemimi; Nawfal Alhelfi; Salam A Ibrahim
Journal:  Biosensors (Basel)       Date:  2020-05-30

Review 9.  Application of Aptamer-Based Biosensor for Rapid Detection of Pathogenic Escherichia coli.

Authors:  Yu-Wen Zhao; Hai-Xia Wang; Guang-Cheng Jia; Zheng Li
Journal:  Sensors (Basel)       Date:  2018-08-01       Impact factor: 3.576

Review 10.  Electrochemical Immuno- and Aptamer-Based Assays for Bacteria: Pros and Cons over Traditional Detection Schemes.

Authors:  Rimsha Binte Jamal; Stepan Shipovskov; Elena E Ferapontova
Journal:  Sensors (Basel)       Date:  2020-09-28       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.