Literature DB >> 28623113

Does Robotic Surgical Simulator Performance Correlate With Surgical Skill?

James T Mills1, Helen Y Hougen2, Daniel Bitner2, Tracey L Krupski3, Noah S Schenkman3.   

Abstract

OBJECTIVE: To assess the relationship between robotic surgical simulation performance and the real-life surgical skill of attending surgeons. We hypothesized that simulation performance would not correlate with real-life robotic surgical skill in attending surgeons.
DESIGN: In 2013, Birkmeyer et al. demonstrated an association between laparoscopic surgical performance as determined by expert review of video clips and surgical outcomes. Using that model of expert review, we studied the relationship between robotic simulator performance and real-life surgical skill. Ten attending robotic surgeons performed 4 tasks on the da Vinci Skills Simulator (Camera Targeting 1, Ring Walk 3, Suture Sponge 3, and Energy Dissection 3). Two video clips of a robotic-assisted operation were then recorded for each surgeon. Three expert robotic surgeons reviewed the recordings and rated surgical technique using the Global Evaluative Assessment of Robotic Skills.
SETTING: University of Virginia; Charlottesville, VA; tertiary hospital PARTICIPANTS: All attending surgeons who perform robotic-assisted surgery at our institution were enrolled and completed the study.
RESULTS: The surgeons had a median of 7.25 years of robotic surgical experience with a median of 91 cases (ranging: 20-346 cases) in the last 4 years. Median scores for each simulator task were 87.5%, 39.0%, 77.5%, and 81.5%. Using Pearson's correlation, scores for each of the individual tasks correlated poorly with expert review of intraoperative performance. There was also no correlation (r = -0.0304) between overall simulation score (mean: 70.7 ± 9.6%) and expert video ratings (mean: 3.66 ± 0.32 points).
CONCLUSIONS: There was no correlation between attending surgeons' simulator performance and expert ratings of intraoperative videos based on the Global Evaluative Assessment of Robotic Skills scale. Although novice surgeons may put considerable effort into training on robotic simulators, performance on a simulator may not correlate with attending robotic surgical performance. Development of simulation exercises that guide novice surgeons toward expert performance is needed.
Copyright © 2017 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Patient Care; Practice-Based Learning and Improvement; clinical competence in medical education; education; robotics; simulation center; surgery; training

Mesh:

Year:  2017        PMID: 28623113     DOI: 10.1016/j.jsurg.2017.05.011

Source DB:  PubMed          Journal:  J Surg Educ        ISSN: 1878-7452            Impact factor:   2.891


  4 in total

Review 1.  The association between video-based assessment of intraoperative technical performance and patient outcomes: a systematic review.

Authors:  Saba Balvardi; Anitha Kammili; Melissa Hanson; Carmen Mueller; Melina Vassiliou; Lawrence Lee; Kevin Schwartzman; Julio F Fiore; Liane S Feldman
Journal:  Surg Endosc       Date:  2022-05-12       Impact factor: 4.584

2.  Virtual reality simulation in robot-assisted surgery: meta-analysis of skill transfer and predictability of skill.

Authors:  M W Schmidt; K F Köppinger; C Fan; K-F Kowalewski; L P Schmidt; J Vey; T Proctor; P Probst; V V Bintintan; B-P Müller-Stich; F Nickel
Journal:  BJS Open       Date:  2021-03-05

3.  Development and Validation of a Virtual Reality Simulator for Robot-Assisted Minimally Invasive Liver Surgery Training.

Authors:  Alan Kawarai Lefor; Saúl Alexis Heredia Pérez; Atsushi Shimizu; Hung-Ching Lin; Jan Witowski; Mamoru Mitsuishi
Journal:  J Clin Med       Date:  2022-07-17       Impact factor: 4.964

4.  Expertise in colonoscopy intubation does not predict diagnostic accuracy: a simulation-based study.

Authors:  Andreas S Vilmann; Christian Lachenmeier; Morten Bo S Svendsen; Bo Soendergaard; Yoon S Park; Lars Bo Svendsen; Lars Konge
Journal:  Endosc Int Open       Date:  2022-01-14
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.