Literature DB >> 28622555

Very sensitive electrochemical determination of diuron on glassy carbon electrode modified with reduced graphene oxide-gold nanoparticle-Nafion composite film.

K Zarei1, A Khodadadi2.   

Abstract

In this work, a very sensitive electrochemical sensor based on glassy carbon electrode (GCE) modified with reduced graphene oxide-gold nanoparticles/Nafion (rGO-AuNPs/Nafion) composite film was applied to determine diuron. Synthesized GO was characterized using X-ray diffraction (XRD) and UV-visible spectroscopy. The surface morphology of the rGO-AuNPs/Nafion film was also characterized using scanning electron microscopy and electrochemical impedance spectroscopy. Cyclic voltammetry (CV) and adsorptive differential pulse voltammetry (AdDPV) were applied to investigate the electrochemical response of the diuron on the modified electrode. The electrode showed a linear response at 1.0×10-9-1.0×10-7 M and a detection limit of 0.3nM under the optimized conditions. The effect of some other species on the determination of diuron was investigated and the sensor showed good selectivity for determination of diuron. The constructed sensor was applied to determine diuron in enriched samples of orange juice, mineral and tap water which statistical t-test showed accuracy of method. Also the sensor was applied to obtain diuron content in the tea sample. The reliability of the proposed sensor was confirmed after comparing the results with those obtained using high performance liquid chromatography (HPLC) as a comparative method.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Diuron; Electrochemical determination; Gold nanoparticles; Nafion; Reduced graphene oxide

Mesh:

Substances:

Year:  2017        PMID: 28622555     DOI: 10.1016/j.ecoenv.2017.06.030

Source DB:  PubMed          Journal:  Ecotoxicol Environ Saf        ISSN: 0147-6513            Impact factor:   6.291


  2 in total

1.  Sensitive Carbon Fiber Microelectrode for the Quantification of Diuron in Quality Control of a Commercialized Formulation.

Authors:  Serge Mbokou Foukmeniok; Roland Fabrice Yibor Bako; Ousmane Ilboudo; Yssouf Karanga; Evangéline Njanja; Maxime Pontie; Issa Tapsoba; Ignas Tonle Kenfack; Rousseau Djouaka
Journal:  Int J Anal Chem       Date:  2022-03-11       Impact factor: 1.885

2.  Analytical Performance of Clay Paste Electrode and Graphene Paste Electrode-Comparative Study.

Authors:  Ewelina Skowron; Kaja Spilarewicz-Stanek; Dariusz Guziejewski; Kamila Koszelska; Radovan Metelka; Sylwia Smarzewska
Journal:  Molecules       Date:  2022-03-22       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.