Literature DB >> 28619655

Comparison of the spatial resolution of source imaging techniques in high-density EEG and MEG.

T Hedrich1, G Pellegrino2, E Kobayashi3, J M Lina4, C Grova5.   

Abstract

BACKGROUND: The present study aims at evaluating and comparing electrical and magnetic distributed source imaging methods applied to high-density Electroencephalography (hdEEG) and Magnetoencephalography (MEG) data. We used resolution matrices to characterize spatial resolution properties of Minimum Norm Estimate (MNE), dynamic Statistical Parametric Mapping (dSPM), standardized Low-Resolution Electromagnetic Tomography (sLORETA) and coherent Maximum Entropy on the Mean (cMEM, an entropy-based technique). The resolution matrix provides information of the Point Spread Functions (PSF) and of the Crosstalk functions (CT), this latter being also called source leakage, as it reflects the influence of a source on its neighbors.
METHODS: The spatial resolution of the inverse operators was first evaluated theoretically and then with real data acquired using electrical median nerve stimulation on five healthy participants. We evaluated the Dipole Localization Error (DLE) and the Spatial Dispersion (SD) of each PSF and CT map.
RESULTS: cMEM showed the smallest spatial spread (SD) for both PSF and CT maps, whereas localization errors (DLE) were similar for all methods. Whereas cMEM SD values were lower in MEG compared to hdEEG, the other methods slightly favored hdEEG over MEG. In real data, cMEM provided similar localization error and significantly less spatial spread than other methods for both MEG and hdEEG. Whereas both MEG and hdEEG provided very accurate localizations, all the source imaging methods actually performed better in MEG compared to hdEEG according to all evaluation metrics, probably due to the higher signal-to-noise ratio of the data in MEG.
CONCLUSION: Our overall results show that all investigated methods provide similar localization errors, suggesting very accurate localization for both MEG and hdEEG when similar number of sensors are considered for both modalities. Intrinsic properties of source imaging methods as well as their behavior for well-controlled tasks, suggest an overall better performance of cMEM in regards to spatial resolution and spatial leakage for both hdEEG and MEG. This indicates that cMEM would be a good candidate for studying source localization of focal and extended generators as well as functional connectivity studies.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  EEG; MEG; Resolution matrix; Somatosensory; Source imaging; Spatial resolution

Mesh:

Year:  2017        PMID: 28619655     DOI: 10.1016/j.neuroimage.2017.06.022

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  36 in total

1.  Exploring spatiotemporal neural dynamics of the human visual cortex.

Authors:  Ying Yang; Michael J Tarr; Robert E Kass; Elissa M Aminoff
Journal:  Hum Brain Mapp       Date:  2019-06-23       Impact factor: 5.038

Review 2.  [Neurofeedback for the treatment of chronic tinnitus : Review and future perspectives].

Authors:  T Kleinjung; C Thüring; D Güntensperger; P Neff; M Meyer
Journal:  HNO       Date:  2018-03       Impact factor: 1.284

3.  Transcranial direct current stimulation over the sensory-motor regions inhibits gamma synchrony.

Authors:  Giovanni Pellegrino; Giorgio Arcara; Giovanni Di Pino; Cristina Turco; Matteo Maran; Luca Weis; Francesco Piccione; Hartwig Roman Siebner
Journal:  Hum Brain Mapp       Date:  2019-03-10       Impact factor: 5.038

4.  Multi-Resolution Graph Based Volumetric Cortical Basis Functions From Local Anatomic Features.

Authors:  Damon E Hyde; Jurriaan Peters; Simon K Warfield
Journal:  IEEE Trans Biomed Eng       Date:  2019-03-13       Impact factor: 4.538

5.  Clinical Yield of Electromagnetic Source Imaging and Hemodynamic Responses in Epilepsy: Validation With Intracerebral Data.

Authors:  Chifaou Abdallah; Tanguy Hedrich; Andreas Koupparis; Jawata Afnan; Jeffrey Alan Hall; Jean Gotman; Francois Dubeau; Nicolas von Ellenrieder; Birgit Frauscher; Eliane Kobayashi; Christophe Grova
Journal:  Neurology       Date:  2022-04-26       Impact factor: 11.800

6.  Reproducibility of EEG-MEG fusion source analysis of interictal spikes: Relevance in presurgical evaluation of epilepsy.

Authors:  Rasheda Arman Chowdhury; Giovanni Pellegrino; Ümit Aydin; Jean-Marc Lina; François Dubeau; Eliane Kobayashi; Christophe Grova
Journal:  Hum Brain Mapp       Date:  2017-11-21       Impact factor: 5.038

7.  Clinical yield of magnetoencephalography distributed source imaging in epilepsy: A comparison with equivalent current dipole method.

Authors:  Giovanni Pellegrino; Tanguy Hedrich; Rasheda Arman Chowdhury; Jeffery A Hall; Francois Dubeau; Jean-Marc Lina; Eliane Kobayashi; Christophe Grova
Journal:  Hum Brain Mapp       Date:  2017-10-11       Impact factor: 5.038

8.  Assessing the localization accuracy and clinical utility of electric and magnetic source imaging in children with epilepsy.

Authors:  Eleonora Tamilia; Michel AlHilani; Naoaki Tanaka; Melissa Tsuboyama; Jurriaan M Peters; P Ellen Grant; Joseph R Madsen; Steven M Stufflebeam; Phillip L Pearl; Christos Papadelis
Journal:  Clin Neurophysiol       Date:  2019-01-31       Impact factor: 3.708

9.  A systematic evaluation of source reconstruction of resting MEG of the human brain with a new high-resolution atlas: Performance, precision, and parcellation.

Authors:  Luke Tait; Ayşegül Özkan; Maciej J Szul; Jiaxiang Zhang
Journal:  Hum Brain Mapp       Date:  2021-07-05       Impact factor: 5.038

10.  How cerebral cortex protects itself from interictal spikes: The alpha/beta inhibition mechanism.

Authors:  Giovanni Pellegrino; Tanguy Hedrich; Viviane Sziklas; Jean-Marc Lina; Christophe Grova; Eliane Kobayashi
Journal:  Hum Brain Mapp       Date:  2021-05-18       Impact factor: 5.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.