Literature DB >> 28619385

Rectum and bladder spacing in cervical cancer brachytherapy using a novel injectable hydrogel compound.

Antonio L Damato1, Megan Kassick2, Akila N Viswanathan3.   

Abstract

PURPOSE: The aim of this study was to evaluate injection of a novel hydrogel (TraceIT; Augmenix, Waltham, MA) between the cervix, rectum, and bladder in female cadavers compared with, and in addition to, the current standard of gauze packing, for organ-at-risk sparing in cervical cancer brachytherapy planning. METHODS AND MATERIALS: This brachytherapy cadaver study used T2-weighted MRI and CT imaging to compare three scenarios: (1) gauze packing alone, (2) hydrogel injection placed in the cervical fornices and rectovaginal septum, and (3) gauze packing in conjunction with hydrogel injection. Hydrogel distribution was evaluated. Doses to 2 cm3 volumes (D2cc) for the rectum, bladder, and sigmoid were collected. Statistical significance (p < 0.05) was evaluated using a two-tailed paired t test.
RESULTS: Hydrogel was successfully injected to space the bladder and rectum from the cervix in all five cadavers. The spacer was easily identifiable on both CT and MRI. The use of hydrogel in addition to packing resulted in a 22% decrease in rectum D2cc dose (p = 0.02), a 10% decrease in bladder D2cc (p = 0.27), and no change in sigmoid D2cc dose. No difference was observed between hydrogel only vs. gauze packing only.
CONCLUSIONS: Our results revealed a significant clinically meaningful decrease in rectal D2cc associated with the use of hydrogel in addition to gauze packing-TraceIT hydrogel holds promise as a spacer in cervical cancer therapy.
Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Bladder sparing; Brachytherapy; Cervical cancer; Chemoradiotherapy; Gynecologic cancers; Hydrogel; Organs at risk; Radiotherapy planning; Rectum sparing

Mesh:

Substances:

Year:  2017        PMID: 28619385     DOI: 10.1016/j.brachy.2017.04.236

Source DB:  PubMed          Journal:  Brachytherapy        ISSN: 1538-4721            Impact factor:   2.362


  10 in total

1.  A radiopaque polymer hydrogel as an irreversible electroporation compatible fiducial marker for pancreas stereotactic body radiotherapy.

Authors:  Eric M Anderson; Kenneth Park; Diana J Lu; Nicholas Nissen; Jun Gong; Andrew Hendifar; Alexandra Gangi; Simon Lo; Mitchell Kamrava; Katelyn M Atkins
Journal:  J Radiosurg SBRT       Date:  2020

Review 2.  The role of radioprotective spacers in clinical practice: a review.

Authors:  Qiuying Tang; Feng Zhao; Xiaokai Yu; Lingyun Wu; Zhongjie Lu; Senxiang Yan
Journal:  Quant Imaging Med Surg       Date:  2018-06

3.  Effect of Hyaluronate Acid Injection on Dose-Volume Parameters in Brachytherapy for Cervical Cancer.

Authors:  Rei Kobayashi; Naoya Murakami; Takahito Chiba; Kae Okuma; Koji Inaba; Kana Takahashi; Tomoya Kaneda; Tairo Kashihara; Ayaka Takahashi; Yuri Shimizu; Yuko Nakayama; Tomoyasu Kato; Yoshinori Ito; Hiroshi Igaki
Journal:  Adv Radiat Oncol       Date:  2022-02-06

4.  Development and preclinical testing of a novel biodegradable hydrogel vaginal packing technology for gynecologic high-dose-rate brachytherapy.

Authors:  Matthew Sean Peach; Joanna Moore; Wallis Giles; Justin Trainor; Tim Long; Nicholas Moon; Joseph E Hylton; Timothy N Showalter; Bruce Libby
Journal:  J Contemp Brachytherapy       Date:  2018-08-31

5.  Hyaluronic gel injection into the vesicovaginal septum for high-dose-rate brachytherapy of uterine cervical cancer: an effective approach for bladder dose reduction.

Authors:  Naoya Murakami; Satoshi Shima; Tairo Kashihara; Nikolaos Tselis; Tomoyasu Kato; Yoshiaki Takagawa; Koji Masui; Ken Yoshida; Kana Takahashi; Koji Inaba; Kae Okuma; Hiroshi Igaki; Yuko Nakayama; Jun Itami
Journal:  J Contemp Brachytherapy       Date:  2019-01-29

Review 6.  Basic concepts and applications of functional magnetic resonance imaging for radiotherapy of prostate cancer.

Authors:  Lars E Olsson; Mikael Johansson; Björn Zackrisson; Lennart K Blomqvist
Journal:  Phys Imaging Radiat Oncol       Date:  2019-02-25

7.  Rectum Protection by Rectal Gel Injection in Cervical Cancer Brachytherapy: A Dosimetric Study via Deformable Surface Dose Accumulation and Machine-Learning-Based Discriminative Modeling.

Authors:  Xuetao Wang; Bailin Zhang; Qiang He; Yilin Kong; Zhenhui Dai; Haoyu Meng; Fangjun Huang; Shengfeng Zhang; Yuanhu Zhu; Xiang Tan; Xin Zhen
Journal:  Front Oncol       Date:  2021-04-16       Impact factor: 6.244

8.  An Asian multi-national multi-institutional retrospective study comparing intracavitary versus the hybrid of intracavitary and interstitial brachytherapy for locally advanced uterine cervical carcinoma.

Authors:  Naoya Murakami; Ken Ando; Masumi Murata; Kazutoshi Murata; Tatsuya Ohno; Tomomi Aoshika; Shingo Kato; Noriyuki Okonogi; Anneyuko I Saito; Joo-Young Kim; Yasuo Yoshioka; Shuhei Sekii; Kayoko Tsujino; Chairat Lowanichkiattikul; Poompis Pattaranutaporn; Yuko Kaneyasu; Tomio Nakagawa; Miho Watanabe; Takashi Uno; Rei Umezawa; Keiichi Jingu; Ayae Kanemoto; Masaru Wakatsuki; Katsuyuki Shirai; Hiroshi Igaki; Jun Itami
Journal:  J Radiat Res       Date:  2022-05-18       Impact factor: 2.724

9.  SpaceOAR hydrogel spacer in interstitial brachytherapy for intrapelvic recurrent endometrial cancer.

Authors:  Yoshiaki Takagawa; Jun Itami
Journal:  BJR Case Rep       Date:  2022-03-09

10.  Laparoscopic Allograft Spacer Placement to Minimize Bowel Dose During Re-irradiation with Interstitial Brachytherapy.

Authors:  Shraddha Dalwadi; Anuj Suri; Aparna Kamat; E Brian Butler; Andrew M Farach
Journal:  Cureus       Date:  2019-10-22
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.