Literature DB >> 28618432

Accuracy of Digital vs Conventional Implant Impression Approach: A Three-Dimensional Comparative In Vitro Analysis.

Kinga Basaki, Hasan Alkumru, Grace De Souza, Yoav Finer.   

Abstract

PURPOSE: To assess the three-dimensional (3D) accuracy and clinical acceptability of implant definitive casts fabricated using a digital impression approach and to compare the results with those of a conventional impression method in a partially edentulous condition.
MATERIALS AND METHODS: A mandibular reference model was fabricated with implants in the first premolar and molar positions to simulate a patient with bilateral posterior edentulism. Ten implant-level impressions per method were made using either an intraoral scanner with scanning abutments for the digital approach or an open-tray technique and polyvinylsiloxane material for the conventional approach. 3D analysis and comparison of implant location on resultant definitive casts were performed using laser scanner and quality control software. The inter-implant distances and interimplant angulations for each implant pair were measured for the reference model and for each definitive cast (n = 20 per group); these measurements were compared to calculate the magnitude of error in 3D for each definitive cast. The influence of implant angulation on definitive cast accuracy was evaluated for both digital and conventional approaches. Statistical analysis was performed using t test (α = .05) for implant position and angulation. Clinical qualitative assessment of accuracy was done via the assessment of the passivity of a master verification stent for each implant pair, and significance was analyzed using chi-square test (α = .05).
RESULTS: A 3D error of implant positioning was observed for the two impression techniques vs the reference model, with mean ± standard deviation (SD) error of 116 ± 94 μm and 56 ± 29 μm for the digital and conventional approaches, respectively (P = .01). In contrast, the inter-implant angulation errors were not significantly different between the two techniques (P = .83). Implant angulation did not have a significant influence on definitive cast accuracy within either technique (P = .64). The verification stent demonstrated acceptable passive fit for 11 out of 20 casts and 18 out of 20 casts for the digital and conventional methods, respectively (P = .01).
CONCLUSION: Definitive casts fabricated using the digital impression approach were less accurate than those fabricated from the conventional impression approach for this simulated clinical scenario. A significant number of definitive casts generated by the digital technique did not meet clinically acceptable accuracy for the fabrication of a multiple implant-supported restoration.

Entities:  

Year:  2017        PMID: 28618432     DOI: 10.11607/jomi.5431

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  9 in total

1.  A new 3D-method to assess the inter implant dimensions in patients - A pilot study.

Authors:  Alexander Schmidt; Jan-Wilhelm Billig; Maximiliane A Schlenz; Bernd Wöstmann
Journal:  J Clin Exp Dent       Date:  2020-02-01

2.  In Vitro Comparison of Three Intraoral Scanners for Implant-Supported Dental Prostheses.

Authors:  Vitória Costa; António Sérgio Silva; Rosana Costa; Pedro Barreiros; Joana Mendes; José Manuel Mendes
Journal:  Dent J (Basel)       Date:  2022-06-15

3.  Three-Dimensional Accuracy of Digital Impression versus Conventional Method: Effect of Implant Angulation and Connection Type.

Authors:  Marzieh Alikhasi; Hakime Siadat; Alireza Nasirpour; Mahya Hasanzade
Journal:  Int J Dent       Date:  2018-06-04

Review 4.  The direct digital workflow in fixed implant prosthodontics: a narrative review.

Authors:  George Michelinakis; Dimitrios Apostolakis; Phophi Kamposiora; George Papavasiliou; Mutlu Özcan
Journal:  BMC Oral Health       Date:  2021-01-21       Impact factor: 2.757

Review 5.  Accuracy of Digital Dental Implants Impression Taking with Intraoral Scanners Compared with Conventional Impression Techniques: A Systematic Review of In Vitro Studies.

Authors:  María Isabel Albanchez-González; Jorge Cortés-Bretón Brinkmann; Jesús Peláez-Rico; Carlos López-Suárez; Verónica Rodríguez-Alonso; María Jesús Suárez-García
Journal:  Int J Environ Res Public Health       Date:  2022-02-11       Impact factor: 3.390

6.  Trueness of digital implant impressions based on implant angulation and scan body materials.

Authors:  Jae-Hyun Lee; Jae-Hwi Bae; Su Young Lee
Journal:  Sci Rep       Date:  2021-11-08       Impact factor: 4.379

7.  3D cone-beam C.T. imaging used to determine the effect of disinfection protocols on the dimensional stability of full arch impressions.

Authors:  Kuei-Ling Hsu; Abdulrahman A Balhaddad; Isadora Martini Garcia; Fabrício Mezzomo Collares; Vineet Dhar; Louis DePaola; Mary Anne Melo
Journal:  Saudi Dent J       Date:  2020-12-10

8.  Accuracy of digital impressions versus conventional impressions for 2 implants: an in vitro study evaluating the effect of implant angulation.

Authors:  Jaafar Abduo; Joseph E A Palamara
Journal:  Int J Implant Dent       Date:  2021-07-30

9.  The Accuracy of Open-Tray vs. Snap on Impression Techniques in A 6-Implant Model: An In Vitro 3D Study.

Authors:  Adi Arieli; Maram Adawi; Mahmoud Masri; Evgeny Weinberg; Ilan Beitlitum; Raphael Pilo; Shifra Levartovsky
Journal:  Materials (Basel)       Date:  2022-03-12       Impact factor: 3.623

  9 in total