Literature DB >> 28618060

Clinical validation of the nursing diagnosis of ineffective protection in haemodialysis patients.

Jéssica Dantas de Sá Tinôco1, Maria das Graças Mariano Nunes de Paiva1, Cecília Maria Farias de Queiroz Frazão2, Kadyjina Daiane Batista Lucio1, Maria Isabel da Conceição Dias Fernandes1, Marcos Venicios de Oliveira Lopes3, Ana Luisa Brandão de Carvalho Lira4.   

Abstract

AIMS AND
OBJECTIVES: To evaluate the clinical validity of indicators of the nursing diagnosis of "ineffective protection" in haemodialysis patients.
BACKGROUND: Haemodialysis patients have reduced protection. Studies on the nursing diagnosis of "ineffective protection" are scarce in the literature. The use of indicators to diagnose "ineffective protection" could improve the care of haemodialysis patients. The clinical usefulness of the indicators requires clinical validation.
DESIGN: This was a diagnostic accuracy study.
METHOD: This study assessed a sample of 200 patients undergoing haemodialysis in a reference clinic for nephrology during the first half of 2015. Operational definitions were created for each clinical indicator based on concept analysis and content validation by experts for these indicators. Diagnostic accuracy measurement was performed with latent class analysis with randomised effects.
RESULTS: The clinical indicator of "fatigue" had high sensitivity (p = .999) and specificity (p = 1.000) for the identification of "ineffective protection." Additionally, "maladaptive response to stress" (p = .711) and "coagulation change" (p = .653) were sensitive indicators. The main indicators that showed high specificity were "fever" (p = .987), "increased number of hospitalisations" (p = .911), "weakness" (p = .937), "infected vascular access" (p = .962) and "vascular access dysfunction" (p = .722).
CONCLUSION: A set of nine clinical indicators of "ineffective protection" were accurate and statistically significant for haemodialysis patients. Three clinical indicators showed sensitivity, and six indicators showed specificity. RELEVANCE TO CLINICAL PRACTICE: Accurate measures for nursing diagnoses can help nurses confirm or rule out the probability of the occurrence of "ineffective protection" in patients undergoing haemodialysis.
© 2017 John Wiley & Sons Ltd.

Entities:  

Keywords:  clinical validation; nursing; nursing diagnosis; protection; renal dialysis

Mesh:

Year:  2017        PMID: 28618060     DOI: 10.1111/jocn.13915

Source DB:  PubMed          Journal:  J Clin Nurs        ISSN: 0962-1067            Impact factor:   3.036


  2 in total

Review 1.  Responses Presented by Adult Patients with COVID-19, Based on the Formulated Nursing Diagnoses: A Scoping Review.

Authors:  Vanessa Cortinhal; António Pereira; Sofia Correia; Sérgio Deodato
Journal:  Int J Environ Res Public Health       Date:  2022-05-23       Impact factor: 4.614

2.  Assessment of Cardiovascular Risk Factors in Young Adults through the Nursing Diagnosis: A Cross-Sectional Study among International University Students.

Authors:  Gonzalo Duarte-Clíments; Tibelle Freitas Mauricio; Juan Gómez-Salgado; Rafaella Pessoa Moreira; Macarena Romero-Martín; María Begoña Sánchez-Gómez
Journal:  Healthcare (Basel)       Date:  2021-01-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.