Literature DB >> 28613351

Comparative Study of Clinical, Ultrasonographic, Conventional Imaging, and Ultra-Wide-Field Fundus for Measurements of the Longest Basal Diameter of Choroidal Tumors.

Bernadete Ayres, Andrew Stacey, Joshua Grant, Tanya McClendon, Hakan Demirci.   

Abstract

BACKGROUND AND
OBJECTIVE: To compare the maximum basal diameter of choroidal tumors measured by clinical estimation and different imaging methods in intraocular tumors for therapeutic planning. PATIENTS AND METHODS: Retrospective, observational study reviewing the measurements of the longest basal diameter of choroidal tumors using the clinical estimation based on the indirect ophthalmoscopy, ophthalmic ultrasonography, 50° fundus imaging, ultra-wide-field imaging color composite, red laser, and green laser.
RESULTS: The study included measurements of 74 tumors in 74 eyes. Correlation analysis between imaging measurements and clinical estimates led to following results: ultra-wide-field imaging measurements were 2.7% to 7.1% smaller than estimated clinical measurements by indirect ophthalmoscopy; followed by ultrasound, with 10.9% smaller measurements; and 50° fundus imaging, measuring 25.8% smaller than clinical estimates. When evaluating the precision of tumor measurements, ultrasound resulted in the highest precision, with a standard error of 1.6 mm compared to clinical estimates, followed by other imaging techniques with standard errors ranging from 2.4 mm to 3.0 mm. Determination of tumor margins with the ultrasound technique was better defined when subretinal fluid was present, or when the height of the tumor was greater than 3 mm.
CONCLUSION: The authors' results suggest that measurements of the longest basal diameter of choroidal tumors can be accurately performed with ultrasound and ultra-wide-field color composite or red laser images. In the presence of subretinal fluid or tumor height above 3 mm, ultrasound can better delineate tumor margins. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:459-464.]. Copyright 2017, SLACK Incorporated.

Entities:  

Mesh:

Year:  2017        PMID: 28613351     DOI: 10.3928/23258160-20170601-03

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers Imaging Retina        ISSN: 2325-8160            Impact factor:   1.300


  3 in total

1.  Portable ultra-widefield fundus camera for multispectral imaging of the retina and choroid.

Authors:  Devrim Toslak; Taeyoon Son; Muhammet Kazim Erol; Hoonsup Kim; Tae-Hoon Kim; R V Paul Chan; Xincheng Yao
Journal:  Biomed Opt Express       Date:  2020-10-12       Impact factor: 3.732

Review 2.  Ultra-wide field retinal imaging: A wider clinical perspective.

Authors:  Vinod Kumar; Abhidnya Surve; Devesh Kumawat; Brijesh Takkar; Shorya Azad; Rohan Chawla; Daraius Shroff; Atul Arora; Ramandeep Singh; Pradeep Venkatesh
Journal:  Indian J Ophthalmol       Date:  2021-04       Impact factor: 1.848

Review 3.  Widefield imaging of retinal and choroidal tumors.

Authors:  Natalia F Callaway; Prithvi Mruthyunjaya
Journal:  Int J Retina Vitreous       Date:  2019-12-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.