Technology in Rehabilitation: Comparing Personalised and Global Classification Methodologies in Evaluating the Squat Exercise with Wearable IMUs.

Darragh F Whelan1, Martin A O'Reilly, Tomás E Ward, Eamonn Delahunt, Brian Caulfield.   

Abstract

BACKGROUND: The barbell squat is a popularly used lower limb rehabilitation exercise. It is also an integral exercise in injury risk screening protocols. To date athlete/patient technique has been assessed using expensive laboratory equipment or subjective clinical judgement; both of which are not without shortcomings. Inertial measurement units (IMUs) may offer a low cost solution for the objective evaluation of athlete/patient technique. However, it is not yet known if global classification techniques are effective in identifying naturally occurring, minor deviations in barbell squat technique.
OBJECTIVES: The aims of this study were to: (a) determine if in combination or in isolation, IMUs positioned on the lumbar spine, thigh and shank are capable of distinguishing between acceptable and aberrant barbell squat technique; (b) determine the capabilities of an IMU system at identifying specific natural deviations from acceptable barbell squat technique; and (c) compare a personalised (N=1) classifier to a global classifier in identifying the above.
METHODS: Fifty-five healthy volunteers (37 males, 18 females, age = 24.21 +/- 5.25 years, height = 1.75 +/- 0.1 m, body mass = 75.09 +/- 13.56 kg) participated in the study. All participants performed a barbell squat 3-repetition maximum max strength test. IMUs were positioned on participants' lumbar spine, both shanks and both thighs; these were utilized to record tri-axial accelerometer, gyroscope and magnetometer data during all repetitions of the barbell squat exercise. Technique was assessed and labelled by a Chartered Physiotherapist using an evaluation framework. Features were extracted from the labelled IMU data. These features were used to train and evaluate both global and personalised random forests classifiers.
RESULTS: Global classification techniques produced poor accuracy (AC), sensitivity (SE) and specificity (SP) scores in binary classification even with a 5 IMU set-up in both binary (AC: 64%, SE: 70%, SP: 28%) and multi-class classification (AC: 59%, SE: 24%, SP: 84%). However, utilising personalised classification techniques even with a single IMU positioned on the left thigh produced good binary classification scores (AC: 81%, SE: 81%, SP: 84%) and moderate-to-good multi-class scores (AC: 69%, SE: 70%, SP: 89%).
CONCLUSIONS: There are a number of challenges in developing global classification exercise technique evaluation systems for rehabilitation exercises such as the barbell squat. Building large, balanced data sets to train such systems is difficult and time intensive. Minor, naturally occurring deviations may not be detected utilising global classification approaches. Personalised classification approaches allow for higher accuracy and greater system efficiency for end-users in detecting naturally occurring barbell squat technique deviations. Applying this approach also allows for a single-IMU set up to achieve similar accuracy to a multi-IMU setup, which reduces total system cost and maximises system usability.

Entities:  

Keywords:  Exercise therapy; biomedical technology; inertial measurement units; lower extremity; physical therapy speciality

Mesh:

Year:  2017        PMID: 28612890     DOI: 10.3414/ME16-01-0141

Source DB:  PubMed          Journal:  Methods Inf Med        ISSN: 0026-1270            Impact factor:   2.176


  5 in total

Review 1.  Wearable Inertial Sensor Systems for Lower Limb Exercise Detection and Evaluation: A Systematic Review.

Authors:  Martin O'Reilly; Brian Caulfield; Tomas Ward; William Johnston; Cailbhe Doherty
Journal:  Sports Med       Date:  2018-05       Impact factor: 11.136

2.  Noninvasive Continuous Monitoring of Vital Signs With Wearables: Fit for Medical Use?

Authors:  Malte Jacobsen; Till A Dembek; Guido Kobbe; Peter W Gaidzik; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2020-02-17

Review 3.  A Systematic Review of Wearable Sensors for Monitoring Physical Activity.

Authors:  Annica Kristoffersson; Maria Lindén
Journal:  Sensors (Basel)       Date:  2022-01-12       Impact factor: 3.576

4.  Application of Magnetic Resonance DTI Technique in Evaluating the Effect of Postoperative Exercise Rehabilitation.

Authors:  Jinping Sheng; Rui Jiang; Feizhou Du; Yang Wang; Xiao Zhang
Journal:  J Healthc Eng       Date:  2022-03-21       Impact factor: 2.682

5.  A Systematic Review on the Use of Wearable Body Sensors for Health Monitoring: A Qualitative Synthesis.

Authors:  Annica Kristoffersson; Maria Lindén
Journal:  Sensors (Basel)       Date:  2020-03-09       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.