Literature DB >> 28612164

Increasing efficiency of MRE for diagnosis of Crohn's disease activity through proper sequence selection: a practical approach for clinical trials.

Jordi Rimola1, Almudena Alvarez-Cofiño2, Tamara Pérez-Jeldres3, Sonia Rodríguez4, Ignacio Alfaro5, Ingrid Ordás5, Elena Ricart5,6, Julián Panés5,6.   

Abstract

PURPOSE: To derive the best magnetic resonance enterography (MRE) approach for detecting activity and severe lesions in Crohn's disease (CD) to use for selecting patients and measuring response to treatment in clinical trials.
METHODS: We compared the accuracies of MRE (T2-weighted sequences, DWI (b = 800 s/mm2) sequences, combined T2-weighted and DWI sequences, combined T2-weighted or DWI sequences, and MaRIA score based on T2-weighted and contrast-enhanced T1-weighted sequences) versus ileocolonoscopy (SES-CD) performed within 1 month. Bowel segments were classified as inactive (SES-CD < 2), active (SES-CD ≥ 2), or active with severe lesions (ulcers seen at endoscopy). McNemar's test was used to compare the accuracies of the different approaches against endoscopy.
RESULTS: 224 segments in 43 patients were analyzed. For detecting active disease, the combination of findings from T2 and DWI sequences results in the highest specific and accurate sequence combination. Combined T2-weighted and DWI sequences had similar sensitivity to those of MaRIA (P = 0.25) but lower specificity (P = 0.007) and accuracy (P = 0.0013) than MaRIA score. For detecting severe lesions, T2-weighted sequences alone had greater accuracy [similar to MaRIA score (P > 0.999)] than other noncontrast approaches.
CONCLUSIONS: T2-weighted sequences should be used as a first screening step, and followed by contrast-enhanced T1-weighted sequences only when abnormal findings are identified; adding DWI does not improve the accuracy of MRE.

Entities:  

Keywords:  Activity; Crohn’s disease; MR enterography; MaRIA

Mesh:

Substances:

Year:  2017        PMID: 28612164     DOI: 10.1007/s00261-017-1203-7

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  5 in total

1.  Evaluation of ileal Crohn's disease response to TNF antagonists: Validation of MR enterography for assessing response. Initial results.

Authors:  Sonja Gordic; Octavia Bane; Shingo Kihira; Steven Peti; Stefanie Hectors; Joana Torres; Judy Cho; Jean-Frederic Colombel; Bachir Taouli
Journal:  Eur J Radiol Open       Date:  2020-01-28

Review 2.  A review of magnetic resonance enterography-based indices for quantification of Crohn's disease inflammation.

Authors:  Noa Rozendorn; Marianne Michal Amitai; Rami Abraham Eliakim; Uri Kopylov; Eyal Klang
Journal:  Therap Adv Gastroenterol       Date:  2018-04-13       Impact factor: 4.409

3.  Fast Magnetic Resonance Enterography Protocol for the Evaluation of Patients with Crohn's Disease: A Pilot Study.

Authors:  Giuseppe Cicero; Stefania Mondello; Julian L Wichmann; Moritz H Albrecht; Thomas J Vogl; Marco Cavallaro; Luciano Frosina; Tommaso D'Angelo; Silvio Mazziotti
Journal:  J Clin Imaging Sci       Date:  2020-05-02

4.  Can MR Enterography and Diffusion-Weighted Imaging Predict Disease Activity Assessed by Simple Endoscopic Score for Crohn's Disease?

Authors:  Levent Soydan; Ali Aslan Demir; Serhat Ozer; Selvinaz Ozkara
Journal:  J Belg Soc Radiol       Date:  2019-01-18       Impact factor: 1.894

5.  Can diffusion weighted imaging be used as an alternative to contrast-enhanced imaging on magnetic resonance enterography for the assessment of active inflammation in Crohn disease?

Authors:  Aysegul Cansu; Suleyman Bekircavusoglu; Sukru Oguz; Eser Bulut; Sami Fidan
Journal:  Medicine (Baltimore)       Date:  2020-02       Impact factor: 1.817

  5 in total