Literature DB >> 28609203

Evaluation of Hepatic Steatosis by Using Acoustic Structure Quantification US in a Rat Model: Comparison with Pathologic Examination and MR Spectroscopy.

Dong Ho Lee1, Jae Young Lee1, Kyung Bun Lee1, Joon Koo Han1.   

Abstract

Purpose To determine factors that significantly affect the focal disturbance (FD) ratio calculated with an acoustic structure quantification (ASQ) technique in a dietary-induced fatty liver disease rat model and to assess the diagnostic performance of the FD ratio in the assessment of hepatic steatosis by using histopathologic examination as a standard of reference. Materials and Methods Twenty-eight male F344 rats were fed a methionine-choline-deficient diet with a variable duration (3.5 days [half week] or 1, 2, 3, 4, 5, or 6 weeks; four rats in each group). A control group of four rats was maintained on a standard diet. At the end of each diet period, ASQ ultrasonography (US) and magnetic resonance (MR) spectroscopy were performed. Then, the rat was sacrificed and histopathologic examination of the liver was performed. Receiver operating characteristic curve analysis was performed to assess the diagnostic performance of the FD ratio in the evaluation of the degree of hepatic steatosis. The Spearman correlation coefficient was calculated to assess the correlation between the ordinal values, and multivariate linear regression analysis was used to identify significant determinant factors for the FD ratio. Results The diagnostic performance of the FD ratio in the assessment of the degree of hepatic steatosis (area under the receiver operating characteristic curve: 1.000 for 5%-33% steatosis, 0.981 for >33% to 66% steatosis, and 0.965 for >66% steatosis) was excellent and was comparable to that of MR spectroscopy. There was a strong negative linear correlation between the FD ratio and the estimated fat fraction at MR spectroscopy (Spearman ρ, -0.903; P < .001). Multivariate linear regression analysis showed that the degree of hepatic steatosis (P < .001) and fibrosis stage (P = .022) were significant factors affecting the FD ratio. Conclusion The FD ratio may potentially provide good diagnostic performance in the assessment of the degree of hepatic steatosis, with a strong negative linear correlation with the estimated fat fraction at MR spectroscopy. The degree of steatosis and stage of fibrosis at histopathologic examination were significant factors that affected the FD ratio. © RSNA, 2017 Online supplemental material is available for this article.

Entities:  

Mesh:

Year:  2017        PMID: 28609203     DOI: 10.1148/radiol.2017161923

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Hepatic steatosis assessment using ultrasound homodyned-K parametric imaging: the effects of estimators.

Authors:  Zhuhuang Zhou; Qiyu Zhang; Weiwei Wu; Ying-Hsiu Lin; Dar-In Tai; Jeng-Hwei Tseng; Yi-Ru Lin; Shuicai Wu; Po-Hsiang Tsui
Journal:  Quant Imaging Med Surg       Date:  2019-12

2.  Quantitative Evaluation of Hepatic Steatosis Using Normalized Local Variance in a Rat Model: Comparison with Histopathology as the Reference Standard.

Authors:  Jae Seok Bae; Jae Young Lee; Dong Ho Lee; Haeryoung Kim; Youngeun Lee; Joon Koo Han
Journal:  Korean J Radiol       Date:  2019-09       Impact factor: 3.500

3.  Reproducibility of ultrasound attenuation imaging for the noninvasive evaluation of hepatic steatosis.

Authors:  Jeongin Yoo; Jeong Min Lee; Ijin Joo; Dong Ho Lee; Jeong Hee Yoon; Hyo-Jin Kang; Su Joa Ahn
Journal:  Ultrasonography       Date:  2019-08-12

4.  Ultrasound Entropy Imaging of Nonalcoholic Fatty Liver Disease: Association with Metabolic Syndrome.

Authors:  Ying-Hsiu Lin; Yin-Yin Liao; Chih-Kuang Yeh; Kuen-Cheh Yang; Po-Hsiang Tsui
Journal:  Entropy (Basel)       Date:  2018-11-22       Impact factor: 2.524

Review 5.  Quantitative Evaluation of Hepatic Steatosis Using Advanced Imaging Techniques: Focusing on New Quantitative Ultrasound Techniques.

Authors:  Junghoan Park; Jeong Min Lee; Gunwoo Lee; Sun Kyung Jeon; Ijin Joo
Journal:  Korean J Radiol       Date:  2022-01       Impact factor: 3.500

Review 6.  Basic concept and clinical applications of quantitative ultrasound (QUS) technologies.

Authors:  Tadashi Yamaguchi
Journal:  J Med Ultrason (2001)       Date:  2021-10-20       Impact factor: 1.314

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.