Determination of secondhand smoke leakage from the smoking room of an Internet café.

Hyejin Kim1, Kiyoung Lee1, Jaehoon An2, Sungho Won2.   

Abstract

Although Internet cafes have been designated as nonsmoking areas in Korea, smoke-free legislation has allowed the installation of indoor smoking rooms. The purposes of this study were to determine secondhand smoke (SHS) leakage from an Internet café smoking room and to identify factors associated with SHS leakage. PM2.5 (particulate matter with an aerodynamic diameter ≤2.5 μm) mass concentrations were measured simultaneously both inside and outside the door to the smoking room. During each measurement, a field technician observed how long the smoking room door was opened and closed, the direction of door opening, and the number of smokers. A multivariate linear regression model was used to identify the causality of SHS leakage from the smoking room. A time series of PM2.5 concentrations both inside and outside the door to the smoking room showed a similar trend. SHS leakage was significantly increased because of factors associated with the direction of the smoking room door being opened, the duration of how long the smoking room door was opened until it was closed, and the average PM2.5 concentration inside the smoking room when the door was opened. SHS leakage from inside the smoking room to outside the smoking room was evident especially when the smoking room door was opened. Since the smoking room is not effective in preventing SHS exposure, the smoking room should be removed from the facilities to protect citizens from SHS exposure through revision of the current legislation, which permits installation of a smoking room. IMPLICATIONS: This paper concerns secondhand smoke (SHS) leakage from indoor smoking room. Unlike previous studies, the authors statistically analyzed the causality of PM2.5 concentration leakage from a smoking room using time-series analysis. Since the authors selected the most common smoking room, the outcomes could be generalized. The study demonstrated that SHS leakage from smoking room and SHS leakage were clearly associated with door opening. The finding demonstrated ineffectiveness of smoking room to protect citizens and supports removal of indoor smoking room.

Mesh:

Substances:

Year:  2017        PMID: 28609195     DOI: 10.1080/10962247.2017.1338205

Source DB:  PubMed          Journal:  J Air Waste Manag Assoc        ISSN: 1096-2247            Impact factor:   2.235


  1 in total

1.  Ranking the environmental factors of indoor air quality of metropolitan independent coffee shops by Random Forests model.

Authors:  Yu-Wen Lin; Chin-Sheng Tang; Hsi-Chen Liu; Tzu-Ying Lee; Hsiao-Yun Huang; Tzu-An Hsu; Li-Te Chang
Journal:  Sci Rep       Date:  2022-09-26       Impact factor: 4.996

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.