Literature DB >> 28606434

The Relationships Between Surface Measurements and Underlying Tendon Autograft Length for Upper Extremity Reconstructive Surgery.

Michael T Milone1, Mikael Starecki2, Omri Ayalon2, Michael W Aversano2, Anthony Sapienza2.   

Abstract

PURPOSE: The availability of tendon grafts is an important consideration for successful upper extremity reconstructive surgery, including flexor or extensor tendon reconstructions, tendon transfers, and ligament reconstructions. Graft selection is based on availability, expendability, ease of harvest, and length. Given variations in patient height and extremity length, existing average values may provide suboptimal insight into actual tendon lengths available. The purpose of this study is, therefore, to pursue a method of estimating available donor tendon lengths based on easily measured anatomical surface landmarks.
METHODS: Thirty cadaveric upper and lower extremity limbs were dissected and the length of commonly harvested tendon grafts including the palmaris longus, extensor indicis proprius, extensor digiti minimi, plantaris, and second long toe extensor was measured. Surface forearm length (from finger tip to cubital fossa) and surface fibular length (from lateral malleolus to fibular head) were also measured. Correlations between surface measurements and underlying tendon lengths were analyzed, and linear models were generated that predicted tendon length as a function of surface measurements.
RESULTS: Surface measurements were correlated with underlying tendon length (R = 0.46 - 0.66). Linear models could predict tendon lengths based on surface measurements. A ratio of donor tendon length compared with the limb segment measured was established for each tendon and can be applied to estimate donor tendon length. For the upper extremity tendons, the multipliers for the palmaris longus, extensor indicis proprius, and extensor digiti minimi were 0.51, 0.20, and 0.18, respectively. Lower extremity tendon ratios for the plantaris and extensor digitorum longus were 0.69 and 0.60, respectively.
CONCLUSIONS: Although length of available donor tendon can be a limiting variable at the time of surgery, surgeons may be better able to estimate underlying tendon lengths using easily obtained superficial measurements. CLINICAL RELEVANCE: Information obtained from these cadaveric measurements may aid in preoperative planning in hand and upper extremity surgery.
Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Upper extremity; anatomy; autograft; cadaver; reconstruction

Mesh:

Year:  2017        PMID: 28606434     DOI: 10.1016/j.jhsa.2017.05.015

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  1 in total

Review 1.  Morphometric analysis and surgical adequacy of palmaris longus as a tendon graft. A systematic review of cadaveric studies.

Authors:  Kaissar Yammine; Mirela Erić
Journal:  Surg Radiol Anat       Date:  2019-11-18       Impact factor: 1.246

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.