Literature DB >> 28605610

Effect of Light-Curing Exposure Time, Shade, and Thickness on the Depth of Cure of Bulk Fill Composites.

A Rodriguez, P Yaman, J Dennison, D Garcia.   

Abstract

PURPOSE: To investigate the effect of different light exposure times, shades, and thicknesses on the depth of cure (DOC) of bulk fill composites. METHODS AND MATERIALS: Two bulk fill composites, Tetric EvoCeram Bulk Fill (TBF) and Sonic Fill (SF), and a conventional composite, Filtek Supreme Ultra (FSU), were evaluated. Samples (n=10) were made using two different shades (light and dark), thicknesses (2 and 4 mm) and exposure times (20 and 40 seconds). A Tukon 2100B-testing machine was used to obtain three Knoop hardness numbers (KHNs) measured at the top and bottom of each sample, and DOC was calculated as the bottom/top ratio. Statistical analysis was done using a Student t-test for comparisons between groups with a Bonferroni correction of p < 0.004.
RESULTS: Top hardness values ranged from 79.79 to 85.07 for FSU, 69.49 to 91.65 for SF, and 51.01 to 57.82 for TBF. Bottom KHNs ranged from 23.54 to 73.25 for FSU, 45.74 to 77.12 for SF, and 36.95 to 52.51 for TBF. TBF had the lowest overall KHNs. Light-curing exposure time, shade, and material thickness influenced the DOC in most groups, especially at 4-mm depths. A higher bottom/top ratio was achieved when a 40-second cure was compared to a 20-second cure, when light shades were compared to dark shades, and when 2-mm increments were compared to 4-mm increments.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28605610     DOI: 10.2341/16-057-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  5 in total

1.  Evaluation of microhardness, sorption, solubility, and color stability of bulk fill resins: A comparative study.

Authors:  Luís-Felipe Espíndola-Castro; Márcia-de Almeida Durão; Tacyandra-Victória-Gomes Pereira; Ayanne-Karine-de Barros Cordeiro; Gabriela-Queiroz-de Melo Monteiro
Journal:  J Clin Exp Dent       Date:  2020-11-01

2.  Use of Artificial Neural Network in Determination of Shade, Light Curing Unit, and Composite Parameters' Effect on Bottom/Top Vickers Hardness Ratio of Composites.

Authors:  Hacer Deniz Arısu; Evrim Eligüzeloglu Dalkilic; Fehime Alkan; Sebnem Erol; Mine Betul Uctasli; Alican Cebi
Journal:  Biomed Res Int       Date:  2018-11-12       Impact factor: 3.411

3.  The Effect of Shade and Thickness on the Depth of Cure of Bulk-Fill Composites with Different Viscosities.

Authors:  Maryam Novin Rooz; Atefeh Yousefi Jordehi
Journal:  J Dent (Shiraz)       Date:  2020-12

4.  Evaluation of Microhardness of Two Bulk-fill Composite Resins Compared to a Conventional Composite Resin on surface and in Different Depths.

Authors:  Keyvan Saati; Sheida Khansari; Farnaz Mahdisiar; Sara Valizadeh
Journal:  J Dent (Shiraz)       Date:  2022-03

5.  Infection Control Barrier and Curing Time as Factors Affecting the Irradiance of Light-Cure Units.

Authors:  Reem A Ajaj; Hani M Nassar; Fatin A Hasanain
Journal:  J Int Soc Prev Community Dent       Date:  2018-11-29
  5 in total