Literature DB >> 28605314

The Validity and Reliability of Knee Proprioception Measurement Performed With Inclinometer in Different Positions.

Sinem Suner-Keklik1, Gamze Cobanoglu-Seven1, Nihan Kafa1, Mustafa Ugurlu2, Nevin Atalay Guzel1.   

Abstract

CONTEXT: Proprioception is the basic element of the spontaneous control of movement, balance and joint stability. Therefore, it is necessary for the execution of walking and daily and sport activities. Loss of proprioception of the knee, which may cause a new injury, is important to evaluate the position sense of the joint during the rehabilitation period. However, the evaluation methods that are used are very expensive, complicated and non-portable, or the measuring method is difficult to implement.
OBJECTIVE: We demonstrated the validity and reliability of knee proprioception measurements performed in the open kinetic chain position and closed kinetic chain position with a dual inclinometer.
DESIGN: We assessed the validity and intra-tester reliability of a digital inclinometer for measuring the knee joint position sense in different positions.
SETTING: Clinical laboratory. PARTICIPANTS: We enrolled 22 participants (age = 21.8 ± 0.95 years, height = 172 ± 9.1 cm, weight = 64.9 ± 14 kg) into the study. INTERVENTION: The same investigator used an inclinometer to take knee proprioception measurements in open and closed kinetic chain positions. MAIN OUTCOME MEASURES: The relative angular error was calculated by taking the arithmetic average of the difference between the target angle and reproduced angle and was the main outcome measure.
RESULTS: We found that the dynamometer-inclinometer had a moderate ICC value (ICC = 0.594, SEM = 1.60, p = 0.005), whereas inclinometer t1 vs inclinometer t2 (ICC = 0.778, SEM = 0.62, p < 0.001) and closed kinetic chain position t1 and closed kinetic chain position t2 (ICC = 0.888, SEM = 0.63, p < 0.001) had high ICC values.
CONCLUSION: Knee proprioception measurements performed with a dual inclinometer were reliable in the closed kinetic chain position in healthy, sedentary individuals and were valid and reliable in the open kinetic chain position.

Entities:  

Keywords:  inclinometer; knee joint; proprioception

Mesh:

Year:  2017        PMID: 28605314     DOI: 10.1123/jsr.2017-0010

Source DB:  PubMed          Journal:  J Sport Rehabil        ISSN: 1056-6716            Impact factor:   1.931


  6 in total

1.  Proprioceptive Changes in Bilateral Knee Joints Following Unilateral Anterior Cruciate Ligament Injury in Cynomolgus Monkeys.

Authors:  Lei Zhang; Ji Qi; Yan Zeng; Shaoqun Zhang; Shijie Fu; Xin Zhou; Ruiyue Ping; Yikai Li
Journal:  Med Sci Monit       Date:  2018-01-06

2.  Sensory retraining of the leg after stroke: systematic review and meta-analysis.

Authors:  Fenny Sf Chia; Suzanne Kuys; Nancy Low Choy
Journal:  Clin Rehabil       Date:  2019-03-22       Impact factor: 3.477

3.  The effects of total knee arthroplasty on knee proprioception of patients with knee osteoarthritis: a meta-analysis.

Authors:  Ya-Yue Xue; Jing-Nan Shi; Kuan Zhang; Hao-Hua Zhang; Song-Hua Yan
Journal:  J Orthop Surg Res       Date:  2022-05-07       Impact factor: 2.677

4.  The Mediating Role of Vision in the Relationship between Proprioception and Postural Control in Older Adults, as Compared to Teenagers and Younger and Middle-Aged Adults.

Authors:  Ainhoa Nieto-Guisado; Monica Solana-Tramunt; Adrià Marco-Ahulló; Marta Sevilla-Sánchez; Cristina Cabrejas; Josep Campos-Rius; Jose Morales
Journal:  Healthcare (Basel)       Date:  2022-01-05

5.  Reliability and validity of the multidimensional dyspnea profile in hospitalized Chinese patients with respiratory diseases.

Authors:  Huaying Chen; Yamin Li; Weihong Wang; Huilin Zhang; Na Nie; Jinnan Ou; Lezhi Li
Journal:  SAGE Open Med       Date:  2021-09-22

6.  Evaluation of proprioception in patients who underwent ACL reconstruction: measurement in functional position

Authors:  Sinem Suner Keklik; Nevin Güzel; Gamze Çobanoğlu; Nihan Kafa; Muhammet Baybars Ataoğlu; Zekeriya Öztemür
Journal:  Turk J Med Sci       Date:  2021-08-30       Impact factor: 0.973

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.