Literature DB >> 28603384

Rapid Measurement of Room Temperature Ionic Liquid Electrochemical Gas Sensor using Transient Double Potential Amperometry.

Hao Wan1, Heyu Yin1, Andrew J Mason1.   

Abstract

Intense study on gas sensors has been conducted to implement fast gas sensing with high sensitivity, reliability and long lifetime. This paper presents a rapid amperometric method for gas sensing based on a room temperature ionic liquid electrochemical gas sensor. To implement a miniaturized sensor with a fast response time, a three electrode system with gold interdigitated electrodes was fabricated by photolithography on a porous polytetrafluoroethylene substrate that greatly enhances gas diffusion. Furthermore, based on the reversible reaction of oxygen, a new transient double potential amperometry (DPA) was explored for electrochemical analysis to decrease the measurement time and reverse reaction by-products that could cause current drift. Parameters in transient DPA including oxidation potential, oxidation period, reduction period and sample point were investigated to study their influence on the performance of the sensor. Oxygen measurement could be accomplished in 4 s, and the sensor presented a sensitivity of 0.2863 μA/[%O2] and a linearity of 0.9943 when tested in air samples with different oxygen concentrations. Repeatability and long-term stability were also investigated, and the sensor was shown to exhibit good reliability. In comparison to conventional constant potential amperometry, transient DPA was shown to reduce relative standard deviation by 63.2%. With transient DPA, the sensitivity, linearity, repeatability, measurement time and current drift characteristics demonstrated by the presented gas sensor are promising for acute exposure applications.

Entities:  

Keywords:  double potential amperometry; gas sensor; oxygen detection; room temperature ionic liquid (RTIL)

Year:  2017        PMID: 28603384      PMCID: PMC5464423          DOI: 10.1016/j.snb.2016.11.103

Source DB:  PubMed          Journal:  Sens Actuators B Chem        ISSN: 0925-4005            Impact factor:   7.460


  14 in total

1.  An electrochemical gas sensor based on paper supported room temperature ionic liquids.

Authors:  Nicolò Dossi; Rosanna Toniolo; Andrea Pizzariello; Emanuel Carrilho; Evandro Piccin; Simone Battiston; Gino Bontempelli
Journal:  Lab Chip       Date:  2011-11-10       Impact factor: 6.799

2.  Use of room temperature ionic liquids in gas sensor design.

Authors:  Marisa C Buzzeo; Christopher Hardacre; Richard G Compton
Journal:  Anal Chem       Date:  2004-08-01       Impact factor: 6.986

Review 3.  Analytical chemistry of nitric oxide.

Authors:  Evan M Hetrick; Mark H Schoenfisch
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2009       Impact factor: 10.745

Review 4.  Flammability of gas mixtures. Part 1: fire potential.

Authors:  Volkmar Schröder; Maria Molnarne
Journal:  J Hazard Mater       Date:  2005-05-20       Impact factor: 10.588

5.  Ionic liquids as electrolytes for the development of a robust amperometric oxygen sensor.

Authors:  Zhe Wang; Peiling Lin; Gary A Baker; Joseph Stetter; Xiangqun Zeng
Journal:  Anal Chem       Date:  2011-08-29       Impact factor: 6.986

6.  Electrochemical sensing of ethylene employing a thin ionic-liquid layer.

Authors:  Marcel A G Zevenbergen; Daan Wouters; Van-Anh T Dam; Sywert H Brongersma; Mercedes Crego-Calama
Journal:  Anal Chem       Date:  2011-07-20       Impact factor: 6.986

7.  Detection and classification of gaseous sulfur compounds by solid electrolyte cyclic voltammetry of cermet sensor array.

Authors:  Kirsten E Kramer; Susan L Rose-Pehrsson; Mark H Hammond; Duane Tillett; Holger H Streckert
Journal:  Anal Chim Acta       Date:  2006-11-12       Impact factor: 6.558

Review 8.  Health effects of air pollution.

Authors:  Jonathan A Bernstein; Neil Alexis; Charles Barnes; I Leonard Bernstein; Jonathan A Bernstein; Andre Nel; David Peden; David Diaz-Sanchez; Susan M Tarlo; P Brock Williams
Journal:  J Allergy Clin Immunol       Date:  2004-11       Impact factor: 10.793

Review 9.  Human health effects of air pollution.

Authors:  Marilena Kampa; Elias Castanas
Journal:  Environ Pollut       Date:  2007-07-23       Impact factor: 8.071

Review 10.  Metal oxide semi-conductor gas sensors in environmental monitoring.

Authors:  George F Fine; Leon M Cavanagh; Ayo Afonja; Russell Binions
Journal:  Sensors (Basel)       Date:  2010-06-01       Impact factor: 3.576

View more
  2 in total

1.  Miniaturized Planar Room Temperature Ionic Liquid Electrochemical Gas Sensor for Rapid Multiple Gas Pollutants Monitoring.

Authors:  Hao Wan; Heyu Yin; Lu Lin; Xiangqun Zeng; Andrew J Mason
Journal:  Sens Actuators B Chem       Date:  2017-08-18       Impact factor: 7.460

2.  A New Low-Temperature Electrochemical Hydrocarbon and NOx Sensor.

Authors:  Praveen Kumar Sekhar; Zachary Moore; Shyam Aravamudhan; Ajit Khosla
Journal:  Sensors (Basel)       Date:  2017-11-29       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.