Literature DB >> 28602825

Comparative evaluation of the effectiveness of the implantation in the lateral part of the mandible between short tissue level (TE) and bone level (BL) implant systems.

Jakub Hadzik1, Ute Botzenhart2, Maciej Krawiec1, Tomasz Gedrange3, Friedhelm Heinemann4, Andras Vegh5, Marzena Dominiak1.   

Abstract

Short dental implants can be an alternative method of treatment to a vertical bone augmentation procedure at sites of reduced alveolar height. However, for successful treatment, an implant system that causes a minimal marginal bone loss (MBL) should be taken into consideration. The aim of the study has been to evaluate implantation effectiveness for bone level and tissue level short implants provided in lateral aspects of partially edentulous mandible and limited alveolar ridge height. The MBL and primary as well as secondary implant stability were determined in the study. Patients were randomly divided into two groups according to the method of treatment provided. Sixteen short Bone Level Implants (OsseoSpeed TX, Astra tech) and 16 short Tissue Level Implants (RN SLActive®, Straumann) were successfully placed in the edentulous part of the mandible. The determination of the marginal bone level was based on radiographic evaluation after 12 and 36 weeks. Implant stability was measured immediately after insertion and after 12 weeks. The marginal bone level of Bone Level Implants was significantly lower compared to Tissue Level Implants. Furthermore, the Bone Level Implants had greater primary and secondary stability in comparison with Tissue Level Implants (Primary: 77.8 ISQ versus 66.5 ISQ; Secondary: 78.9 ISQ versus 73.9 ISQ, respectively). Since short Bone Level Implants showed a significantly decreased MBL 12 and 36 weeks after implantation as well as better results for the primary stability compared to Tissue Level Implants, they should preferentially be used for this mentioned indication.
Copyright © 2017 Elsevier GmbH. All rights reserved.

Entities:  

Keywords:  Implant stability; Marginal bone level; Radiographic measurement; Short implants

Mesh:

Substances:

Year:  2017        PMID: 28602825     DOI: 10.1016/j.aanat.2017.05.008

Source DB:  PubMed          Journal:  Ann Anat        ISSN: 0940-9602            Impact factor:   2.698


  6 in total

1.  The Characterization of Titanium Particles Released from Bone-Level Titanium Dental Implants: Effect of the Size of Particles on the Ion Release and Cytotoxicity Behaviour.

Authors:  Juan Antonio Callejas; Aritza Brizuela; Blanca Ríos-Carrasco; Javier Gil
Journal:  Materials (Basel)       Date:  2022-05-19       Impact factor: 3.748

2.  An evaluation of superhydrophilic surfaces of dental implants - a systematic review and meta-analysis.

Authors:  Arkadiusz Makowiecki; Jakub Hadzik; Artur Błaszczyszyn; Tomasz Gedrange; Marzena Dominiak
Journal:  BMC Oral Health       Date:  2019-05-10       Impact factor: 2.757

Review 3.  Bone loss-related factors in tissue and bone level dental implants: a systematic review of clinical trials.

Authors:  Hamed Mortazavi; Amin Khodadoustan; Aida Kheiri; Lida Kheiri
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2021-06-30

4.  The Influence of the Crown-Implant Ratio on the Crestal Bone Level and Implant Secondary Stability: 36-Month Clinical Study.

Authors:  Jakub Hadzik; Maciej Krawiec; Konstanty Sławecki; Christiane Kunert-Keil; Marzena Dominiak; Tomasz Gedrange
Journal:  Biomed Res Int       Date:  2018-05-16       Impact factor: 3.411

5.  Radiological Outcomes of Bone-Level and Tissue-Level Dental Implants: Systematic Review.

Authors:  Saverio Cosola; Simone Marconcini; Michela Boccuzzi; Giovanni Battista Menchini Fabris; Ugo Covani; Miguel Peñarrocha-Diago; David Peñarrocha-Oltra
Journal:  Int J Environ Res Public Health       Date:  2020-09-22       Impact factor: 3.390

6.  Analysis of Peri-Implant Bone Loss with a Convergent Transmucosal Morphology: Retrospective Clinical Study.

Authors:  María Costa Castillo; Martín Laguna Martos; Rocío Marco Pitarch; Marina García Selva; Silvia Del Cid Rodríguez; Carla Fons-Badal; Rubén Agustín Panadero
Journal:  Int J Environ Res Public Health       Date:  2022-03-15       Impact factor: 3.390

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.