Literature DB >> 28602194

Online coupling of fully automatic in-syringe dispersive liquid-liquid microextraction with oxidative back-extraction to inductively coupled plasma spectrometry for sample clean-up in elemental analysis: A proof of concept.

Burkhard Horstkotte1, Kateřina Fikarová2, David J Cocovi-Solberg3, Hana Sklenářová2, Petr Solich2, Manuel Miró4.   

Abstract

A proof of concept of a novel automatic sample cleanup approach for metal assays in troublesome matrixes as a front-end sample pre-treatment to inductively coupled plasma optical emission spectroscopy - ICP-OES - is herein presented. Target metals, namely, copper, lead, and cadmium were complexed in-system quantitatively using ammonium pyrrolidine dithiocarbamate (APDC) and transferred into a minute volume of toluene as extractant employing lab-in-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction (LIS-MSA-DLLME). After discharge of the sample, the analytes were back-extracted into nitric acid and injected on-line into ICP-OES. To promote and expedite this process in-syringe, advantage was taken from oxidative decomposition of the chelate by potassium iodate, reported in this article for the first time. Experimental conditions for LIS-MSA-DLLME were optimized by Box-Benkhen multivariate analysis using the geometric mean of analyte recoveries as the desirability function. Times of extraction and back-extraction of 300s and 100s, respectively, pH 5.5 at 30mmol/L acetate, 300µL of extraction solvent, and 600µmol/L of APDC were finally applied. Online interfacing to ICP-OES for back-extract analysis yielded average repeatabilities for Cd, Cu, and Pb of 2.9%, 3.5%, and 3.5% with limits of detections (3s) of 1.9, 1.4, and 5.6ng/mL, respectively. Oxidative back-extraction was proven reliable for the determination of metal species in coastal seawater, surrogate digestive fluids and soil leachates with recovery values for Cd, Cu, and Pb ranging from 90% to 118%, 68% to 104%, and 86% to 112%, respectively.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Automatic sample cleanup; Dispersive liquid-liquid microextraction; ICP-OES; Lab-in-syringe; Oxidative Back-extraction

Year:  2017        PMID: 28602194     DOI: 10.1016/j.talanta.2017.05.063

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  3 in total

1.  Comparison Studies on Several Ligands Used in Determination of Cd(II) in Rice by Flame Atomic Absorption Spectrometry after Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction.

Authors:  Qian Sun; Xinyu Cui; Yanfeng Wang; Pingping Zhang; Wenjuan Lu
Journal:  Molecules       Date:  2022-01-18       Impact factor: 4.411

2.  Fully-automated magnetic stirring-assisted lab-in-syringe dispersive liquid-liquid microextraction for the determination of arsenic species in rice samples.

Authors:  Xiaojun Wang; Guoliang Xu; Peng Chen; Yueshu Sun; Xiaoting Yao; Yan Lv; Weiwei Guo; Guozhen Wang
Journal:  RSC Adv       Date:  2018-05-08       Impact factor: 3.361

3.  The Automation Technique Lab-In-Syringe: A Practical Guide.

Authors:  Burkhard Horstkotte; Petr Solich
Journal:  Molecules       Date:  2020-04-01       Impact factor: 4.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.