Literature DB >> 28600692

Simultaneous determination of pyrethroids and pyrethrins by dispersive liquid-liquid microextraction and liquid chromatography triple quadrupole mass spectrometry in environmental samples.

Alexander Ccanccapa-Cartagena1, Ana Masiá2, Yolanda Picó2.   

Abstract

A simple and environmentally friendly dispersive liquid-liquid microextraction (DLLME) method coupled with electrospray ionization liquid chromatography triple quadrupole mass spectrometry (LC-QqQ-MS/MS) was developed for the simultaneous determination of 17 synthetic and natural pyrethroids. A comparison of solid-phase extraction (SPE) versus DLLME for water samples and only "dilute and shoot" versus the additional extract cleanup by DLLME for sediment samples is reported. Chloroform was the extracting solvent in the DLLME technique for both water and sediment samples. Ultrasonic energy was applied to fully extract the analytes into fine droplets, providing high recoveries in short times. Method detection limits (MDLs) ranged from 0.12 to 0.62 ng L-1 and recoveries from 70 to 119% with RSD values 2-15% (n = 5) for water samples. In sediment samples, MDLs ranged from 0.50 to 2.50 ng g-1 and recoveries from 71 to 112% with RSDs 2-16% (n = 5). The proposed method showed a good linearity within the range of 10-500 ng mL-1, with coefficients of determination (R 2) higher than 0.99. Matrix effects were observed for most compounds in water and sediment (ME% < -10%). The proposed methodology was applied for the analysis of water and sediment samples from Albufera wetland and Turia River. Acrinathrin (48 ng g-1) and etofenprox (16 ng g-1) were detected in sediment samples. Graphical abstract Pyrethrins and pyrethroid determination in water and sediments by DLLME and LC-MS/MS.

Entities:  

Keywords:  Dispersive liquid-liquid microextraction; Liquid chromatography; Pyrethroids and pyrethrins; Sediment; Triple quadrupole mass spectrometry; Water

Year:  2017        PMID: 28600692     DOI: 10.1007/s00216-017-0422-7

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  Response surface optimization of a vortex-assisted dispersive liquid-liquid microextraction method for highly sensitive determination of repaglinide in environmental water by HPLC/UV.

Authors:  Amira H Kamal; Mohamed A Hammad; Reham E Kannouma; Fotouh R Mansour
Journal:  BMC Chem       Date:  2022-05-14

2.  A Microfluidic Paper-Based Analytical Device for Type-II Pyrethroid Targets in an Environmental Water Sample.

Authors:  Sumate Pengpumkiat; Jintana Nammoonnoy; Watcharaporn Wongsakoonkan; Pajaree Konthonbut; Pornpimol Kongtip
Journal:  Sensors (Basel)       Date:  2020-07-23       Impact factor: 3.576

3.  Liquid Chromatography-Electron Capture Negative Ionization-Tandem Mass Spectrometry Detection of Pesticides in a Commercial Formulation.

Authors:  Achille Cappiello; Veronica Termopoli; Pierangela Palma; Giorgio Famiglini; Mansoor Saeed; Simon Perry; Pablo Navarro
Journal:  J Am Soc Mass Spectrom       Date:  2021-12-13       Impact factor: 3.109

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.