Literature DB >> 28600228

A bimetallic nanocoral Au decorated with Pt nanoflowers (bio)sensor for H2O2 detection at low potential.

Gabriella Sanzò1, Irene Taurino2, Francesca Puppo2, Riccarda Antiochia3, Lo Gorton4, Gabriele Favero3, Franco Mazzei3, Sandro Carrara2, Giovanni De Micheli5.   

Abstract

In this work, we have developed for the first time a method to make novel gold and platinum hybrid bimetallic nanostructures differing in shape and size. Au-Pt nanostructures were prepared by electrodeposition in two simple steps. The first step consists of the electrodeposition of nanocoral Au onto a gold substrate using hydrogen as a dynamic template in an ammonium chloride solution. After that, the Pt nanostructures were deposited onto the nanocoral Au organized in pores. Using Pt (II) and Pt (IV), we realized nanocoral Au decorated with Pt nanospheres and nanocoral Au decorated with Pt nanoflowers, respectively. The bimetallic nanostructures showed better capability to electrochemically oxidize hydrogen peroxide compared with nanocoral Au. Moreover, Au-Pt nanostructures were able to lower the potential of detection and a higher performance was obtained at a low applied potential. Then, glucose oxidase was immobilized onto the bimetallic Au-Pt nanostructure using cross-linking with glutaraldehyde. The biosensor was characterized by chronoamperometry at +0.15V vs. Ag pseudo-reference electrode (PRE) and showed good analytical performances with a linear range from 0.01 to 2.00mM and a sensitivity of 33.66µA/mMcm2. The good value of Kmapp (2.28mM) demonstrates that the hybrid nanostructure is a favorable environment for the enzyme. Moreover, the low working potential can minimize the interference from ascorbic acid and uric acid as well as reducing power consumption to effect sensing. The simple procedure to realize this nanostructure and to immobilize enzymes, as well as the analytical performances of the resulting devices, encourage the use of this technology for the development of biosensors for clinical analysis.
Copyright © 2017. Published by Elsevier Inc.

Entities:  

Keywords:  Au nanocoral; Bimetallic hybrid nanostructure; Glucose oxidase; Hydrogen peroxide; Pt nanoflowers; Pt nanospheres

Mesh:

Substances:

Year:  2017        PMID: 28600228     DOI: 10.1016/j.ymeth.2017.06.005

Source DB:  PubMed          Journal:  Methods        ISSN: 1046-2023            Impact factor:   3.608


  2 in total

1.  Machine learning methods and systems for data-driven discovery in biomedical informatics.

Authors:  Sungroh Yoon; Seunghak Lee; Wei Wang
Journal:  Methods       Date:  2017-10-01       Impact factor: 3.608

2.  Glucose Biosensor Based on Disposable Activated Carbon Electrodes Modified with Platinum Nanoparticles Electrodeposited on Poly(Azure A).

Authors:  Francisco Jiménez-Fiérrez; María Isabel González-Sánchez; Rebeca Jiménez-Pérez; Jesús Iniesta; Edelmira Valero
Journal:  Sensors (Basel)       Date:  2020-08-11       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.