Literature DB >> 28598861

Collimated superfine x-ray beam based x-ray luminescence computed tomography.

Wei Zhang1, Dianwen Zhu1, Michael Lun1, Changqing Li1.   

Abstract

X-ray luminescence computed tomography (XLCT) is a hybrid imaging modality with the potential to achieve a spatial resolution up to several hundred micrometers for targets embedded in turbid media with a depth larger than several millimeters. In this paper, we report a high spatial resolution XLCT imaging system with a collimated superfine x-ray beam in imaging the deeply embedded targets. A collimator with a 100 micrometer pinhole was mounted in the front of a powerful x-ray tube to generate a superfine x-ray pencil beam with a beam diameter of 0.175 mm. For the phantom experiment of four capillary targets with an edge-to-edge distance of 400 micrometers, we were able to reconstruct the targets in a depth of 5 mm successfully, which were validated with microCT images. We have further investigated the effect of different x-ray beam diameters on the reconstructed XLCT images with numerical simulations. Our results indicate that XLCT has the ability to image successfully multiple deeply embedded targets when the collimated x-ray beam diameter is less than or equal to the target edge-to-edge distance. Our numerical simulations also demonstrate that XLCT can achieve a spatial resolution of 200 micrometers for targets embedded at a depth of 5 mm if the scanning beam has a diameter of 100 micrometers.

Entities:  

Keywords:  X-ray imaging; medical opticszzm321990instrumentation; tomography; turbid media

Mesh:

Year:  2017        PMID: 28598861      PMCID: PMC6188660          DOI: 10.3233/XST-17265

Source DB:  PubMed          Journal:  J Xray Sci Technol        ISSN: 0895-3996            Impact factor:   1.535


  13 in total

1.  Tomographic molecular imaging of x-ray-excitable nanoparticles.

Authors:  Guillem Pratx; Colin M Carpenter; Conroy Sun; Ravi P Rao; Lei Xing
Journal:  Opt Lett       Date:  2010-10-15       Impact factor: 3.776

2.  X-ray luminescence computed tomography via selective excitation: a feasibility study.

Authors:  Guillem Pratx; Colin M Carpenter; Conroy Sun; Lei Xing
Journal:  IEEE Trans Med Imaging       Date:  2010-07-08       Impact factor: 10.048

3.  Nonuniform update for sparse target recovery in fluorescence molecular tomography accelerated by ordered subsets.

Authors:  Dianwen Zhu; Changqing Li
Journal:  Biomed Opt Express       Date:  2014-11-12       Impact factor: 3.732

4.  Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging.

Authors:  Hao F Zhang; Konstantin Maslov; George Stoica; Lihong V Wang
Journal:  Nat Biotechnol       Date:  2006-06-25       Impact factor: 54.908

5.  In vivo x-ray luminescence tomographic imaging with single-view data.

Authors:  Xin Liu; Qimei Liao; Hongkai Wang
Journal:  Opt Lett       Date:  2013-11-15       Impact factor: 3.776

6.  Sensitivity study of x-ray luminescence computed tomography.

Authors:  Michael C Lun; Wei Zhang; Changqing Li
Journal:  Appl Opt       Date:  2017-04-10       Impact factor: 1.980

7.  Cone beam x-ray luminescence computed tomography: a feasibility study.

Authors:  Dongmei Chen; Shouping Zhu; Huangjian Yi; Xianghan Zhang; Duofang Chen; Jimin Liang; Jie Tian
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

8.  Nonconvex regularizations in fluorescence molecular tomography for sparsity enhancement.

Authors:  Dianwen Zhu; Changqing Li
Journal:  Phys Med Biol       Date:  2014-05-15       Impact factor: 3.609

9.  X-ray luminescence optical tomography imaging: experimental studies.

Authors:  Changqing Li; Kun Di; Julien Bec; Simon R Cherry
Journal:  Opt Lett       Date:  2013-07-01       Impact factor: 3.776

10.  Spatial resolution of confocal XRF technique using capillary optics.

Authors:  Maël Dehlinger; Carole Fauquet; Sebastien Lavandier; Orawan Aumporn; Franck Jandard; Vladimir Arkadiev; Aniouar Bjeoumikhov; Didier Tonneau
Journal:  Nanoscale Res Lett       Date:  2013-06-07       Impact factor: 4.703

View more
  2 in total

1.  X-ray luminescence computed tomography using a focused x-ray beam.

Authors:  Wei Zhang; Michael C Lun; Alex Anh-Tu Nguyen; Changqing Li
Journal:  J Biomed Opt       Date:  2017-11       Impact factor: 3.170

2.  Method for improving the spatial resolution of narrow x-ray beam-based x-ray luminescence computed tomography imaging.

Authors:  Yueming Zhang; Michael C Lun; Changqing Li; Zhongxing Zhou
Journal:  J Biomed Opt       Date:  2019-08       Impact factor: 3.170

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.