Literature DB >> 28595947

Comparison of Temporal Artery Versus Rectal Temperature in Emergency Department Patients Who Are Unable to Participate in Oral Temperature Assessment.

Carmen Brosinski1, Sherwin Valdez2, Autumn Riddell2, Robert H Riffenburgh2.   

Abstract

INTRODUCTION: In the emergency department, pediatric and geriatric patients who present with illnesses and are unable to participate in oral evaluation of temperature must undergo a rectal temperature (RT) assessment. This study asks if a temporal artery temperature (TAT) measure can supplant the RT measure.
METHODS: A convenience sample, using a within-subject design, was used to evaluate the efficacy of TAT compared with RT in patients ≤ 3 and ≥ 65 years of age, who were unable to participate in oral temperature assessments.
RESULTS: Instrument reliability of the TAT is adequate for both the pediatric and geriatric populations. An unadjusted TAT did not provide acceptable temperature measurements. We also found that adjusting a TAT reading by adding -17.22°C (1° F) rendered the TAT average (either mean or median) adequately similar to RT averages for research purposes for both pediatric and geriatric groups. DISCUSSION: No influence was detected on the differences between RT and TAT due to age, sex, or emergency severity index (ESI) score in patients or due to profession, years of education, or years of experience in caregivers for either the pediatric or geriatric groups. Furthermore, the adjusted TAT reading could detect fever in individual patients adequately in both the pediatric and geriatric groups. However, the adjusted TAT readings were too frequently divergent from RT readings to be used to measure temperature in individual patients for both pediatric and geriatric groups. Published by Elsevier Inc.

Entities:  

Keywords:  Emergency nursing; Geriatric temperature; Pediatric temperature; Temporal artery thermometer

Mesh:

Year:  2017        PMID: 28595947     DOI: 10.1016/j.jen.2017.04.015

Source DB:  PubMed          Journal:  J Emerg Nurs        ISSN: 0099-1767            Impact factor:   1.836


  2 in total

Review 1.  The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis.

Authors:  Valentina Pecoraro; Davide Petri; Giorgio Costantino; Alessandro Squizzato; Lorenzo Moja; Gianni Virgili; Ersilia Lucenteforte
Journal:  Intern Emerg Med       Date:  2020-11-25       Impact factor: 3.397

2.  Are Digital Oral Thermometer Readings Accurate in Adult Emergency Department Patients?

Authors:  Ryan J Reece; Mary Hughes
Journal:  Cureus       Date:  2022-02-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.