Literature DB >> 28595842

Preoperative implant selection for unilateral breast reconstruction using 3D imaging with the Microsoft Kinect sensor.

Stefanie T L Pöhlmann1, Elaine Harkness1, Christopher J Taylor1, Ashu Gandhi2, Susan M Astley3.   

Abstract

AIMS: This study aimed to investigate whether breast volume measured preoperatively using a Kinect 3D sensor could be used to determine the most appropriate implant size for reconstruction.
METHODS: Ten patients underwent 3D imaging before and after unilateral implant-based reconstruction. Imaging used seven configurations, varying patient pose and Kinect location, which were compared regarding suitability for volume measurement. Four methods of defining the breast boundary for automated volume calculation were compared, and repeatability assessed over five repetitions.
RESULTS: The most repeatable breast boundary annotation used an ellipse to track the inframammary fold and a plane describing the chest wall (coefficient of repeatability: 70 ml). The most reproducible imaging position comparing pre- and postoperative volume measurement of the healthy breast was achieved for the sitting patient with elevated arms and Kinect centrally positioned (coefficient of repeatability: 141 ml). Optimal implant volume was calculated by correcting used implant volume by the observed postoperative asymmetry. It was possible to predict implant size using a linear model derived from preoperative volume measurement of the healthy breast (coefficient of determination R2 = 0.78, standard error of prediction 120 ml). Mastectomy specimen weight and experienced surgeons' choice showed similar predictive ability (both: R2 = 0.74, standard error: 141/142 ml). A leave one-out validation showed that in 61% of cases, 3D imaging could predict implant volume to within 10%; however for 17% of cases it was >30%.
CONCLUSION: This technology has the potential to facilitate reconstruction surgery planning and implant procurement to maximise symmetry after unilateral reconstruction.
Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  3D imaging; Breast reconstruction; Implant selection; Kinect; Mastectomy

Mesh:

Year:  2017        PMID: 28595842     DOI: 10.1016/j.bjps.2017.04.005

Source DB:  PubMed          Journal:  J Plast Reconstr Aesthet Surg        ISSN: 1748-6815            Impact factor:   2.740


  6 in total

Review 1.  The current progress and critical analysis of three-dimensional scanning and three-dimensional printing applications in breast surgery.

Authors:  S A Alshehri; S K Singh; A Mosahebi; D M Kalaskar
Journal:  BJS Open       Date:  2021-05-07

2.  Use of Commercial Off-The-Shelf Devices for the Detection of Manual Gestures in Surgery: Systematic Literature Review.

Authors:  Fernando Alvarez-Lopez; Marcelo Fabián Maina; Francesc Saigí-Rubió
Journal:  J Med Internet Res       Date:  2019-04-14       Impact factor: 5.428

3.  Predictive value of 3D imaging to guide implant selection in immediate breast reconstruction.

Authors:  Monica Yu; Mary-Helen Mahoney; Gordon Soon; Brian Pinchuk; Ron Somogyi
Journal:  JPRAS Open       Date:  2021-10-29

4.  Automated Breast Volume Assessment Derived From Digital Breast Tomosynthesis Images Compared to Mastectomy Specimen Weight and Its Applications in Cosmetic Optimisation.

Authors:  Asma Munir; Anita M Huws; Saira Khawaja; Sohail Khan; Simon Holt; Yousef Sharaiha
Journal:  Cureus       Date:  2021-11-16

5.  Nonrigid reconstruction of 3D breast surfaces with a low-cost RGBD camera for surgical planning and aesthetic evaluation.

Authors:  R M Lacher; F Vasconcelos; N R Williams; G Rindermann; J Hipwell; D Hawkes; D Stoyanov
Journal:  Med Image Anal       Date:  2019-01-11       Impact factor: 8.545

6.  Prediction of the Ideal Implant Size Using 3-Dimensional Healthy Breast Volume in Unilateral Direct-to-Implant Breast Reconstruction.

Authors:  Jeong-Hoon Kim; Jin-Woo Park; Kyong-Je Woo
Journal:  Medicina (Kaunas)       Date:  2020-09-24       Impact factor: 2.430

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.