The purpose of this study was to characterize the heterogeneity of oxygen partial pressure in different adipose tissue zones and to assess the possibility of compensating these heterogeneities during optical glucose measurements. In this proof of concept study, the heterogeneity of oxygen partial pressure was determined in the adipose tissue of a pig by using 48 oxygen sensors in 3 zones of the abdominal region at two different blood oxygen levels. Sensor oxygen values correlated well with reference blood oxygen values and we identified heterogeneities in oxygen partial pressure among the defined zones of the abdominal region. Significant differences in the mean oxygen partial pressure were found when comparing the three abdominal zones but no significant differences were found when comparing two sensors located in close proximity (on one cannula). The low heterogeneity on one cannula allows the compensation of physiological oxygen variations for optical glucose measurements by using an additional oxygen sensor in close proximity to the glucose sensor. In addition, this setup can be used to continuously monitor tissue oxygenation e.g. in patients with adipose tissue dysfunction or serve limb ischemia.

Entities:  

Keywords:  Optical glucose measurement; Optical oxygen sensor; Oxygen distribution; Tissue monitoring

Mesh:

Substances:

Year:  2017        PMID: 28593455     DOI: 10.1007/s10877-017-0034-y

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  4 in total

1.  The First-in-Man "Si Se Puede" Study for the use of micro-oxygen sensors (MOXYs) to determine dynamic relative oxygen indices in the feet of patients with limb-threatening ischemia during endovascular therapy.

Authors:  Miguel F Montero-Baker; Kit Yee Au-Yeung; Natalie A Wisniewski; Soya Gamsey; Luis Morelli-Alvarez; Joseph L Mills; Marianella Campos; Kristen L Helton
Journal:  J Vasc Surg       Date:  2015-06       Impact factor: 4.268

2.  First application of a transcutaneous optical single-port glucose monitoring device in patients with type 1 diabetes mellitus.

Authors:  M Rumpler; J K Mader; J P Fischer; R Thar; J M Granger; F Deliane; I Klimant; F Aberer; F Sinner; T R Pieber; M Hajnsek
Journal:  Biosens Bioelectron       Date:  2016-08-13       Impact factor: 10.618

3.  Red light-excitable oxygen sensing materials based on platinum(II) and palladium(II) benzoporphyrins.

Authors:  S M Borisov; G Nuss; I Klimant
Journal:  Anal Chem       Date:  2008-12-15       Impact factor: 6.986

4.  Adipose tissue oxygenation: Effects on metabolic function.

Authors:  Leanne Hodson
Journal:  Adipocyte       Date:  2013-11-13       Impact factor: 4.534