Literature DB >> 28590322

Off-pump Versus On-pump Coronary Artery Bypass Surgery: Graft Patency Assessment With Coronary Computed Tomographic Angiography: A Prospective Multicenter Randomized Controlled Pilot Study.

Nicolas Noiseux1, Louis-Mathieu Stevens, Carl Chartrand-Lefebvre, Gilles Soulez, Ignacio Prieto, Fadi Basile, Samer Mansour, Adel M Dyub, Teresa M Kieser, André Lamy.   

Abstract

PURPOSE: A large multicenter randomized trial (RCT) is needed to assess off-pump coronary artery bypass graft (CABG) patency when performed by skilled surgeons. This prospective multicenter randomized pilot study compares graft patency after on-pump and off-pump techniques and addresses the feasibility of such an RCT.
MATERIALS AND METHODS: Consecutive patients were prospectively recruited for ≥64-slice computed tomography angiography graft patency assessment 1 year after randomization to off-pump or on-pump CABG. Blinded assessment of graft patency was performed, and the results were categorized as normal, ≥50% stenosis, or occlusion. A multilevel model with random effects on the patient was used to account for correlation of results in patients with multiple grafts.
RESULTS: A total of 157 patients (3 centers, 84 off-pump and 73 on-pump patients, 512 grafts, assessability rate 98.4%) were included. Patency index (% nonoccluded grafts) was 89% for the off-pump technique and 95% for the on-pump technique (P=0.09). Patency was similar for arterial and vein grafts (both 92%; P=0.88), as well as between target territories (89% to 94%; P=0.53).
CONCLUSIONS: In this pilot study, 1-year graft patency results after off-pump and on-pump surgery were similar. This feasibility trial demonstrates that a large multicenter RCT to compare CABG patency after on-pump with that after off-pump techniques is feasible and can be reliably undertaken using computed tomography angiography.

Entities:  

Mesh:

Year:  2017        PMID: 28590322     DOI: 10.1097/RTI.0000000000000277

Source DB:  PubMed          Journal:  J Thorac Imaging        ISSN: 0883-5993            Impact factor:   3.000


  3 in total

1.  CT angiography for coronary graft assessment.

Authors:  Carl Chartrand-Lefebvre; Louis-Mathieu Stevens; Samer Mansour; Nicolas Noiseux
Journal:  J Thorac Dis       Date:  2018-01       Impact factor: 2.895

2.  Incidental findings in CT imaging of coronary artery bypass grafts: results from a Canadian multicenter prospective cohort.

Authors:  I Boldeanu; J Perreault Bishop; S Nepveu; L-M Stevens; G Soulez; T M Kieser; A Lamy; N Noiseux; C Chartrand-Lefebvre
Journal:  BMC Res Notes       Date:  2018-01-25

3.  Development of a risk score for early saphenous vein graft failure: An individual patient data meta-analysis.

Authors:  Alexios S Antonopoulos; Ayodele Odutayo; Evangelos K Oikonomou; Marialena Trivella; Mario Petrou; Gary S Collins; Charalambos Antoniades
Journal:  J Thorac Cardiovasc Surg       Date:  2019-08-26       Impact factor: 5.209

  3 in total