Literature DB >> 28588878

A novel purgative protocol for capsule endoscopy of the small bowel produces better quality of visibility than 2 l of PEG: Timing is of the essence.

Samuel N Adler1, Shai Farkash2, Yishai Sompolinsky3, Inna Gafanovich1, Eran Goldin1, Ariella Bar-Gil Shitrit1.   

Abstract

INTRODUCTION: The ideal way of preparing patients for small-bowel capsule endoscopy has been controversial. Previous studies have shown that ingestion of 2 l of polyethylenglycol (PEG) 12 hours prior to capsule ingestion leads to improved visibility in comparison to no preparation at all. We speculated that using a post-ingestion (PI), booster-based cleansing protocol might provide an alternative to the PEG cleansing protocol.
METHODS: This randomized, blinded, prospective study enrolled 45 individuals. Patients were allocated to either of two groups. The PEG group ingested 2 l PEG 12 hours prior to the exam (n = 22) and the PI group ingested one sachet of Picolax® dissolved in 250 ml of water one hour after swallowing the capsule with 500 ml of water (n = 18). Primary endpoints were overall small bowel and distal third of small bowel cleansing levels. Secondary endpoints were average gastric and small-bowel transit time.
RESULTS: Forty-five patients participated in this study. Five individuals were excluded because of incomplete study. Percentage of patients with adequate visibility in the distal third of the small bowel in the PEG group was 9% vs 72% in the PI group (p < 0.0001). Average gastric time and total transit time were shorter in the PI group vs the PEG group (p = 0.0065).
CONCLUSION: Timing of ingestion of the Picolax® purgative 60 minutes after swallowing the capsule endoscopy delivers better visibility in the distal third of the small bowel than the accepted cleansing protocol of ingesting 2 l PEG 12 hours prior to the capsule endoscopy procedure.

Entities:  

Keywords:  Capsule endoscopy; bowel preparation; purgative; small bowel; upper GI endoscopy

Year:  2016        PMID: 28588878      PMCID: PMC5446143          DOI: 10.1177/2050640616665291

Source DB:  PubMed          Journal:  United European Gastroenterol J        ISSN: 2050-6406            Impact factor:   4.623


  19 in total

1.  PillCamColon Capsule for the study of colonic pathology in clinical practice. Study of agreement with colonoscopy.

Authors:  J M Herrerías-Gutiérrez; F Argüelles-Arias; A Caunedo-Álvarez; M San-Juan-Acosta; J Romero-Vázquez; J M García-Montes; F Pellicer-Bautista
Journal:  Rev Esp Enferm Dig       Date:  2011-02       Impact factor: 2.086

2.  Effect of bowel preparation with polyethylene glycol on quality of capsule endoscopy.

Authors:  Sung Chul Park; Bora Keum; Yeon Seok Seo; Yong Sik Kim; Yoon Tae Jeen; Hoon Jai Chun; Soon Ho Um; Chang Duck Kim; Ho Sang Ryu
Journal:  Dig Dis Sci       Date:  2010-12-16       Impact factor: 3.199

3.  Prospective controlled study on the effects of polyethylene glycol in capsule endoscopy.

Authors:  Takafumi Ito; Ken Ohata; Akiko Ono; Hideyuki Chiba; Yosuke Tsuji; Hajime Sato; Nobuyuki Matsuhashi
Journal:  World J Gastroenterol       Date:  2012-04-21       Impact factor: 5.742

4.  Second-generation colon capsule endoscopy is feasible in the out-of-clinic setting.

Authors:  Samuel Nathan Adler; Cesare Hassan; Yoav Metzger; Yishai Sompolinsky; Cristiano Spada
Journal:  Surg Endosc       Date:  2013-09-17       Impact factor: 4.584

5.  Prospective multicenter performance evaluation of the second-generation colon capsule compared with colonoscopy.

Authors:  R Eliakim; K Yassin; Y Niv; Y Metzger; J Lachter; E Gal; B Sapoznikov; F Konikoff; G Leichtmann; Z Fireman; Y Kopelman; S N Adler
Journal:  Endoscopy       Date:  2009-12-04       Impact factor: 10.093

6.  Bowel preparation for capsule endoscopy: a prospective randomized multicenter study.

Authors:  Jun-Hwan Wi; Jeong-Seop Moon; Myung-Gyu Choi; Jin Oh Kim; Jae Hyuk Do; Ji-Kon Ryu; Ki-Nam Shim; Kwang Jae Lee; Byung Ik Jang; Hoon Jai Chun
Journal:  Gut Liver       Date:  2009-09-30       Impact factor: 4.519

7.  Does purgative preparation influence the diagnostic yield of small bowel video capsule endoscopy?: A meta-analysis.

Authors:  T Rokkas; K Papaxoinis; K Triantafyllou; D Pistiolas; S D Ladas
Journal:  Am J Gastroenterol       Date:  2009-01       Impact factor: 10.864

8.  Bowel preparation increases the diagnostic yield of capsule endoscopy: a prospective, randomized, controlled study.

Authors:  Nikos Viazis; Spiros Sgouros; Kostis Papaxoinis; John Vlachogiannakos; Christina Bergele; Pantelis Sklavos; Anna Panani; Alec Avgerinos
Journal:  Gastrointest Endosc       Date:  2004-10       Impact factor: 9.427

9.  Optimal preparation for video capsule endoscopy: a prospective, randomized, single-blind study.

Authors:  S A C van Tuyl; H den Ouden; M F J Stolk; E J Kuipers
Journal:  Endoscopy       Date:  2007-12       Impact factor: 10.093

Review 10.  Should bowel preparation, antifoaming agents, or prokinetics be used before video capsule endoscopy? A systematic review and meta-analysis.

Authors:  Vikram S Kotwal; Bashar M Attar; Saurabh Gupta; Rajender Agarwal
Journal:  Eur J Gastroenterol Hepatol       Date:  2014-02       Impact factor: 2.566

View more
  4 in total

Review 1.  Optimising the performance and interpretation of small bowel capsule endoscopy.

Authors:  Sabina Beg; Adolfo Parra-Blanco; Krish Ragunath
Journal:  Frontline Gastroenterol       Date:  2017-11-16

2.  Purgative Small Bowel Preparation for Capsule Endoscopy? Maybe, but Think Out of the Box!

Authors:  Paraskevas Gkolfakis; Georgios Tziatzios; Konstantinos Triantafyllou
Journal:  Dig Dis Sci       Date:  2019-11-05       Impact factor: 3.199

3.  Changes in performance of small bowel capsule endoscopy based on nationwide data from a Korean Capsule Endoscopy Registry.

Authors:  Su Hwan Kim; Yun Jeong Lim; Junseok Park; Ki-Nam Shim; Dong-Hoon Yang; Jaeyoung Chun; Jin Su Kim; Hyun Seok Lee; Hoon Jai Chun
Journal:  Korean J Intern Med       Date:  2019-12-30       Impact factor: 2.884

4.  Development of a deep learning-based software for calculating cleansing score in small bowel capsule endoscopy.

Authors:  Ji Hyung Nam; Youngbae Hwang; Dong Jun Oh; Junseok Park; Ki Bae Kim; Min Kyu Jung; Yun Jeong Lim
Journal:  Sci Rep       Date:  2021-02-24       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.