Literature DB >> 28585994

New Technique for Removal of Screws With Damaged Heads.

Takahiro Iwata, Satoshi Nozawa, Masato Maeda, Haruhiko Akiyama.   

Abstract

Removal of orthopedic implants may sometimes be difficult because of ongrowth of new bone. Titanium screws can become encased or stripped during the process of initial open reduction and internal fixation or at the time of hardware removal. Difficulty in removing screws from a locking plate is particularly well-known. Two patients with tibial and femoral diaphyseal fractures were treated using a locking plate or an intramedullary nail. However, after fracture healing, it was difficult to remove the locking screw or reconstruction screws because of damage to the heads. The stripped reconstruction screw was successfully removed employing the authors' so-called parallel planes technique. In this method, a high-speed diamond-tipped burr is applied to opposite sides of the screw head to form 2 parallel faces located slightly away from the recess of the screw head. The 2 faces can then be grasped solidly with locking pliers, allowing removal of the implant by unscrewing it with a gentle upward pulling action. The locking plate was cut from the plate edge to the edge of the screw hole. While making these radial cuts in the plates, the authors were careful not to extend the blade into the screw head. After removal of the locking plate from the screw, the authors were able to extract the jammed screw uneventfully using this technique. This technique can be performed without difficulty and does not require a special device. It is a useful option for extraction of damaged screws. [Orthopedics. 2017; 40(5):e911-e914.]. Copyright 2017, SLACK Incorporated.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28585994     DOI: 10.3928/01477447-20170602-01

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  4 in total

1.  Use of high-speed burr and water-based lubricant in the partial removal of surgical plates: A technique Guide.

Authors:  Jon E Hammarstedt; Grigory E Gershkovich; Daniel P Mass
Journal:  J Clin Orthop Trauma       Date:  2018-05-24

2.  Preparation and Characterization of an Injectable and Photo-Responsive Chitosan Methacrylate/Graphene Oxide Hydrogel: Potential Applications in Bone Tissue Adhesion and Repair.

Authors:  Daniela N Céspedes-Valenzuela; Santiago Sánchez-Rentería; Javier Cifuentes; Mónica Gantiva-Diaz; Julian A Serna; Luis H Reyes; Carlos Ostos; Christian Cifuentes-De la Portilla; Carolina Muñoz-Camargo; Juan C Cruz
Journal:  Polymers (Basel)       Date:  2021-12-30       Impact factor: 4.329

3.  Screw stripping and its prevention in the hexagonal socket of 3.5-mm titanium locking screws.

Authors:  Hyo-Jin Lee; Young Uk Park; Sung Jae Kim; Hyong Nyun Kim
Journal:  Sci Rep       Date:  2021-10-29       Impact factor: 4.379

4.  A Simple Technique for Removal of Interlocking Screw from an Intramedullary Nail: A Case Report.

Authors:  Sumanth Madhusudan Prabhakar; Joshua Decruz; Wee Liang Hao James; Remesh Kunnasegaran
Journal:  J Orthop Case Rep       Date:  2021
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.