Literature DB >> 28583652

Non-contrast-enhanced magnetic resonance venography using magnetization-prepared rapid gradient-echo (MPRAGE) in the preoperative evaluation of living liver donor candidates: Comparison with conventional computed tomography venography.

Rikiya Yamashita1, Hiroyoshi Isoda2, Shigeki Arizono3, Ayako Ono4, Natsuko Onishi5, Akihiro Furuta6, Kaori Togashi7.   

Abstract

OBJECTIVE: To compare the diagnostic performance of non-contrast-enhanced magnetic resonance venography using magnetization-prepared rapid gradient-echo (MPRAGE-MRV) and conventional computed tomography venography (CTV) in preoperative evaluation of venous tributaries for living donor liver transplantation.
MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained for this prospective study of 73 donor candidates. Of these, 23 underwent right-sided graft hepatectomy without middle hepatic vein. One or more tributaries, other than the right hepatic vein, were reconstructed for 20 of the 23 grafts. For these 20 grafts, the number and location of the tributaries requiring reconstruction were evaluated based on venography, and diagnostic performance was analyzed using surgical records as a reference standard. For each candidate, the number of small tributaries directly joining the inferior vena cava was counted in each venographic image; a paired-sample t-test was used to assess differences. The severity of respiratory artifacts in MPRAGE-MRV was qualitatively evaluated, and compared using Wilcoxon's rank-sum test.
RESULTS: All reconstructed venous tributaries were prospectively identified using both methods. MPRAGE-MRV tended to provide a greater number of small tributaries than conventional CTV (mean: 2; 95% CI: [1.66, 2.34], and 1.74; [1.44, 2.04], respectively), although the difference was not significant (P=0.10); MPRAGE-MRV was superior or equal to CTV in 52 subjects (71.2%), and inferior in 21 subjects (28.8%). Respiratory artifacts were significantly less severe in the former subjects (P<0.0001).
CONCLUSIONS: MPRAGE-MRV has the potential to replace conventional CTV in the preoperative evaluation of living liver donor candidates.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Hepatic venous congestion; Living donor liver transplantation; Magnetization-prepared rapid gradient-echo; Non-contrast-enhanced magnetic resonance venography; Outflow reconstruction; Right lobe graft without middle hepatic vein

Mesh:

Year:  2017        PMID: 28583652     DOI: 10.1016/j.ejrad.2017.02.028

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  2 in total

1.  Non-Contrast-Enhanced and Contrast-Enhanced Magnetic Resonance Angiography in Living Donor Liver Vascular Anatomy.

Authors:  Chien-Chang Liao; Meng-Hsiang Chen; Chun-Yen Yu; Leung-Chit Leo Tsang; Chao-Long Chen; Hsien-Wen Hsu; Wei-Xiong Lim; Yi-Hsuan Chuang; Po-Hsun Huang; Yu-Fan Cheng; Hsin-You Ou
Journal:  Diagnostics (Basel)       Date:  2022-02-15

2.  Usefulness of non-contrast-enhanced magnetic resonance imaging prior to venous interventions.

Authors:  Agnieszka Kusiak; Jacek Budzyński
Journal:  Postepy Kardiol Interwencyjnej       Date:  2019-09-18       Impact factor: 1.426

  2 in total