Bruno Bonnechère1, Bart Jansen2,3, Lubos Omelina2,4, Marcel Rooze1, Serge Van Sint Jan1.
Abstract
BACKGROUND: Since 2010, an increasing interest in more portable and flexible hardware for balance and posture assessment led to previously published studies determining whether or not the Wii Balance Board could be used to assess balance and posture, both scientifically and clinically. However, no previous studies aimed at comparing results from different Wii Balance Boards for clinical balance evaluation exist.Entities:
Keywords: balance board; balance performance; force plate; repeatability; validity
Year: 2015 PMID: 28582237 PMCID: PMC5454543 DOI: 10.2196/rehab.3832
Source DB: PubMed Journal: JMIR Rehabil Assist Technol ISSN: 2369-2529
Figure 1Equations.
Intraclass correlation coefficient (ICC) of the studied parameters for the 4 different devices.
| Variable | ICC agreement | Bounds of the confidence interval | Friedman, | |
|
|
| Lower | Upper |
|
| DOT | .704 | -0.110 | 0.955 | .93 |
| Area | .959 | 0.858 | 0.994 | .91 |
| RMSAP | .906 | 0.686 | 0.985 | .42 |
| RMSML | .334 | -1.761 | 0.901 | .87 |
| AdCPAP | .786 | 0.336 | 0.965 | .25 |
| AdCPML | .345 | -1.911 | 0.904 | .72 |
| MVAP | .985 | 0.950 | 0.998 | .95 |
| MVML | .980 | 0.931 | 0.997 | .86 |
| TMV | .984 | 0.945 | 0.997 | .94 |
Figure 2Differences between force plate and Wii Balance Boards for the 72 trials. Solid horizontal lines represent the mean difference. Dotted horizontal lines represent upper and lower confidence intervals (95%). Vertical lines indicate separation between the 4 different devices (18 trials per Wii Balance Board).
Contingency table of the number of observations outside of the confidence interval.
| Variable | Wii Balance Board device number |
| |||
| 1, na | 2, na | 3, na | 4, na | Total, per variable | |
| DOT | 1 (0.05) | 1 (0.05) | 3 (0.16) | 0 (0) | 5 (0.07) |
| Area | 2 (0.11) | 1 (0.05) | 2 (0.11) | 0 (0) | 5 (0.07) |
| RMSAP | 2 (0.11) | 0 (0) | 1 (0.05) | 2 (0.11) | 5 (0.07) |
| RMSML | 1 (0.05) | 0 (0) | 2 (0.11) | 1 (0.05) | 4 (0.06) |
| AdCPAP | 2 (0.11) | 3 (0.16) | 0 (0) | 1 (0.05) | 6 (0.08) |
| AdCPML | 1 (0.05) | 0 (0) | 2 (0.11) | 1 (0.05) | 4 (0.06) |
| MVAP | 0 (0) | 1 (0.05) | 0 (0) | 2 (0.11) | 3 (0.04) |
| MVML | 3 (0.16) | 1 (0.05) | 1 (0.05) | 1 (0.05) | 6 (0.08) |
| TMV | 3 (0.16) | 1 (0.05) | 1 (0.05) | 1 (0.05) | 6 (0.08) |
| Total, per device | 15 (0.09) | 8 (0.05) | 12 (0.07) | 9 (0.05) | 44 |
aValues inside brackets represent the ratio between outside values and number of observations.
Spearman correlation coefficients between the force plate and the 4 different Wii Balance Board devices.
| Variables | Wii Balance Board device number |
| |||
| 1, ρ | 2, ρ | 3, ρ | 4, ρ | Mean, ρ | |
| DOT | .79 | .73 | .73 | .87 | .78 |
| Area | .85 | .89 | .82 | .90 | .86 |
| RMSAP | .79 | .92 | .85 | .78 | .83 |
| RMSML | .85 | .72 | .72 | .80 | .76 |
| AdCPAP | .76 | .89 | .74 | .79 | .80 |
| AdCPML | .89 | .79 | .76 | .73 | .79 |
| MVAP | .94 | .89 | .88 | .90 | .91 |
| MVML | .96 | .84 | .85 | .91 | .89 |
| TMV | .82 | .80 | .77 | .86 | .81 |
| Mean, ρ (SD) | .85 (0.02) | .83 (0.02) | .79 (0.02) | .84 (0.02) | .83 (0.05) |