Literature DB >> 28581287

Electrochemical Detection of Ultratrace (Picomolar) Levels of Hg2+ Using a Silver Nanoparticle-Modified Glassy Carbon Electrode.

Alex L Suherman1, Kamonwad Ngamchuea1, Eden E L Tanner1, Stanislav V Sokolov1, Jennifer Holter2, Neil P Young2, Richard G Compton1.   

Abstract

Ultratrace levels of Hg2+ have been quantified by undertaking linear sweep voltammetry with a silver nanoparticle-modified glassy carbon electrode (AgNP-GCE) in aqueous solutions containing Hg2+. This is achieved by monitoring the change in the silver stripping peak with Hg2+ concentration resulting from the galvanic displacement of silver by mercury: Ag(np) + 1/2Hg2+(aq) → Ag+(aq) + 1/2Hg(l). This facile and reproducible detection method exhibits an excellent linear dynamic range of 100.0 pM to 10.0 nM Hg2+ concentration with R2 = 0.982. The limit of detection (LoD) based on 3σ is 28 pM Hg2+, while the lowest detectable level for quantification purposes is 100.0 pM. This method is appropriate for routine environmental monitoring and drinking water quality assessment since the guideline value set by the US Environmental Protection Agency (EPA) for inorganic mercury in drinking water is 0.002 mg L-1 (10 nM).

Entities:  

Year:  2017        PMID: 28581287     DOI: 10.1021/acs.analchem.7b01304

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Ultrasensitive impedimetric mercury(II) sensor based on thymine-Hg(II)-thymine interaction and subsequent disintegration of multiple sandwich-structured DNA chains.

Authors:  Feng Gao; Taoshun Zhang; Yaru Chu; Qingxiang Wang; Juan Song; Weiwei Qiu; Zhenyu Lin
Journal:  Mikrochim Acta       Date:  2018-11-21       Impact factor: 5.833

2.  Bare eye detection of Hg(II) ions based on enzyme inhibition and using mercaptoethanol as a reagent to improve selectivity.

Authors:  Liuying He; Yuexiang Lu; Feiyang Wang; Xinxin Gao; Ying Chen; Yueying Liu
Journal:  Mikrochim Acta       Date:  2018-02-13       Impact factor: 5.833

Review 3.  Recent Advances in Electrochemical Biosensors for the Detection of Salmonellosis: Current Prospective and Challenges.

Authors:  Subhasis Mahari; Sonu Gandhi
Journal:  Biosensors (Basel)       Date:  2022-05-26

4.  Ultrasensitive determination of mercury ions using a glassy carbon electrode modified with nanocomposites consisting of conductive polymer and amino-functionalized graphene quantum dots.

Authors:  Bowen Tian; Yanxia Kou; Xiangmei Jiang; Jiajia Lu; Yuanyuan Xue; Meijuan Wang; Liang Tan
Journal:  Mikrochim Acta       Date:  2020-03-09       Impact factor: 5.833

Review 5.  Recent developments in voltammetric and amperometric sensors for cysteine detection.

Authors:  Somayeh Tajik; Zahra Dourandish; Peyman Mohammadzadeh Jahani; Iran Sheikhshoaie; Hadi Beitollahi; Mehdi Shahedi Asl; Ho Won Jang; Mohammadreza Shokouhimehr
Journal:  RSC Adv       Date:  2021-01-28       Impact factor: 3.361

6.  Highly Sensitive AgNP/MWCNT/Nafion Modified GCE-Based Sensor for the Determination of Heavy Metals in Organic and Non-organic Vegetables.

Authors:  Shirley Tiong Palisoc; Michelle Tiamzon Natividad; Nico De Jesus; Joshua Carlos
Journal:  Sci Rep       Date:  2018-11-28       Impact factor: 4.379

Review 7.  Glassy Carbon: A Promising Material for Micro- and Nanomanufacturing.

Authors:  Swati Sharma
Journal:  Materials (Basel)       Date:  2018-09-28       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.