Literature DB >> 28576477

Perceptions of transcatheter device closure of patent ductus arteriosus in veterinary cardiology and evaluation of a canine model to simulate device placement: a preliminary study.

A B Saunders1, L Keefe2, S A Birch2, M A Wierzbicki3, D J Maitland3.   

Abstract

OBJECTIVES: The purpose of this study was to evaluate a canine patent ductus arteriosus (PDA) model developed for practicing device placement and to determine practices and perceptions regarding transcatheter closure of PDA from the veterinary cardiology community.
METHOD: A silicone model was developed from images obtained from a dog with a PDA and device placement was performed with catheter equipment and a document camera to simulate fluoroscopy. A total of 36 individuals including 24 diplomates and 12 residents participated, and the feedback was obtained. The study included an initial questionnaire, practice with the model, observation of device placement using the model, and a follow-up questionnaire.
RESULTS: A total of 92% of participants including 100% of residents indicated they did not have the opportunity to practice device placement before performing the procedure and obtained knowledge of the procedure from reading journal articles or observation. Participants indicated selecting the appropriate device size (30/36, 83%) and ensuring the device is appropriately positioned before release (18/36, 50%) as the most common areas of difficulty with device placement. Confidence level was higher after practicing with the model for residents when compared with diplomates and for participants that had performed 1-15 procedures when compared with those that had performed >15 procedures. These findings suggest those that have performed fewer procedures may benefit the most from practicing with a model.
CONCLUSIONS: This preliminary study demonstrates the feasibility of a PDA model for practicing device placement and suggests that there is a potential benefit from providing additional training resources.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Computed tomography; Congenital heart disease; Dog; Simulation; Training

Mesh:

Year:  2017        PMID: 28576477     DOI: 10.1016/j.jvc.2017.04.002

Source DB:  PubMed          Journal:  J Vet Cardiol        ISSN: 1760-2734            Impact factor:   1.701


  2 in total

1.  Comparative, multidimensional imaging of patent ductus arteriosus and a proposed update to the morphology classification system for dogs.

Authors:  Kelley R Doocy; Ashley B Saunders; Sonya G Gordon; Nicholas Jeffery
Journal:  J Vet Intern Med       Date:  2018-02-20       Impact factor: 3.333

2.  Transcatheter closure through single venous approach for young children with patent ductus arteriosus: A retrospective study of 686 cases.

Authors:  Jun Liu; Lei Gao; Hui-Lian Tan; Qing-Hou Zheng; Ling Liu; Zhen Wang
Journal:  Medicine (Baltimore)       Date:  2018-08       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.