Literature DB >> 28575979

Live-cell biosensor for assessment of adhesion qualities of biomaterials.

Svetlana I Ivanova1, Stoyan Chakarov2, Albena Momchilova3, Roumen Pankov4.   

Abstract

The present study describes a live-cell biosensor, suitable for general evaluation of adhesion qualities of different substrates. It is based on NIH/3T3 fibroblast cell line stably expressing fusion fluorescently tagged proteins mCherry-vinculin and GFP-tensin as quantifiable markers for assessment not only of focal but also of fibrillar contacts. Four measurable parameters - spreading, polarization and development of focal and fibrillar adhesions were used to standardize the adhesion of biosensor cells after plating on five substrates of natural origin - fibronectin, vitronectin, laminin-111, laminin-521 and collagen type I. The obtained set of values (adhesion quality map) were utilized to describe the default biosensor behavior and as a standard for evaluation of surface biocompatibility of materials with unknown adhesive properties. To demonstrate the applicability of the biosensor we studied two PDMS-based artificial materials. The results demonstrated the superior adhesive properties of the poly(acrylic acid)-containing polymer (PDMS-PAA) over that of poly(vinyl pyrrolidone) copolymer (PDMS-PVP), and pointed out the formation of focal adhesions as a parameter for possible further improvements.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biocompatibility; Biomaterials; Cell adhesions; Live-cell biosensor; PDMS

Mesh:

Substances:

Year:  2017        PMID: 28575979     DOI: 10.1016/j.msec.2017.04.071

Source DB:  PubMed          Journal:  Mater Sci Eng C Mater Biol Appl        ISSN: 0928-4931            Impact factor:   7.328


  4 in total

1.  Electron Beam Sterilization of Poly(Methyl Methacrylate)-Physicochemical and Biological Aspects.

Authors:  Sina Sharifi; Mohammad Mirazul Islam; Hannah Sharifi; Rakibul Islam; Tahmida N Huq; Per H Nilsson; Tom E Mollnes; Khoa D Tran; Corrina Patzer; Claes H Dohlman; Hirak K Patra; Eleftherios I Paschalis; Miguel Gonzalez-Andrades; James Chodosh
Journal:  Macromol Biosci       Date:  2021-02-24       Impact factor: 4.979

2.  The Influence of the Polymer Amount on the Biological Properties of PCL/ZrO₂ Hybrid Materials Synthesized via Sol-Gel Technique.

Authors:  Michelina Catauro; Elisabetta Tranquillo; Michela Illiano; Luigi Sapio; Annamaria Spina; Silvio Naviglio
Journal:  Materials (Basel)       Date:  2017-10-17       Impact factor: 3.623

3.  Sputter Deposition of Titanium on Poly(Methyl Methacrylate) Enhances Corneal Biocompatibility.

Authors:  Sina Sharifi; Mohammad Mirazul Islam; Hannah Sharifi; Rakibul Islam; Per H Nilsson; Claes H Dohlman; Tom Eirik Mollnes; Eleftherios I Paschalis; James Chodosh
Journal:  Transl Vis Sci Technol       Date:  2020-12-23       Impact factor: 3.283

4.  The Drosophila spectraplakin Short stop regulates focal adhesion dynamics by cross-linking microtubules and actin.

Authors:  Andrew J Zhao; Julia Montes-Laing; Wick M G Perry; Mari Shiratori; Emily Merfeld; Stephen L Rogers; Derek A Applewhite
Journal:  Mol Biol Cell       Date:  2022-03-02       Impact factor: 3.612

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.