Literature DB >> 28575930

Mapping cation exchange capacity using a Veris-3100 instrument and invVERIS modelling software.

T Koganti1, F J Moral2, F J Rebollo3, J Huang1, J Triantafilis4.   

Abstract

The cation exchange capacity (CEC) is one of the most important soil properties as it influences soil's ability to hold essential nutrients. It also acts as an index of structural resilience. In this study, we demonstrate a method for 3-dimensional mapping of CEC across a study field in south-west Spain. We do this by establishing a linear regression (LR) between the calculated true electrical conductivity (σ - mS/m) and measured CEC (cmol(+)/kg) at various depths. We estimate σ by inverting Veris-3100 data (ECa - mS/m) collected along 47 parallel transects spaced 12m apart. We invert the ECa data acquired from both shallow (0-0.3m) and deep (0-0.9m) array configurations, using a quasi-three-dimensional inversion algorithm (invVeris V1.1). The CEC data was acquired at 40 locations and from the topsoil (0-0.3m), subsurface (0.3-0.6m) and subsoil (0.6-0.9m). The best LR between σ and CEC was achieved using S2 inversion algorithm using a damping factor (λ)=18. The LR (CEC=1.77+0.33×σ) had a large coefficient of determination (R2=0.89). To determine the predictive capability of the LR, we validated the model using a cross-validation. Given the high accuracy (root-mean-square-error [RMSE]=1.69 cmol(+)/kg), small bias (mean-error [ME]=-0.00cmol(+)/kg) and large coefficient of determination (R2=0.88) and Lin's concordance (0.94), between measured and predicted CEC and at various depths, we conclude we were well able to predict the CEC distribution in topsoil and the subsurface. However, the predictions made in the subsoil were poor due to limited data availability in areas where ECa changed rapidly from small to large values. In this regard, improvements in prediction accuracy can be achieved by collection of ECa in more closely spaced transects, particularly in areas where ECa varies over short spatial scales.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cation exchange capacity; Digital soil mapping; Electrical conductivity; Proximal soil sensing; Quasi-3d inversion; Shrink-swell potential

Year:  2017        PMID: 28575930     DOI: 10.1016/j.scitotenv.2017.05.074

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  3 in total

1.  Low-Input Estimation of Site-Specific Lime Demand Based on Apparent Soil Electrical Conductivity and In Situ Determined Topsoil pH.

Authors:  Moritz von Cossel; Harm Druecker; Eberhard Hartung
Journal:  Sensors (Basel)       Date:  2019-11-30       Impact factor: 3.576

2.  Delineation of Nitrate Reduction Hotspots in Artificially Drained Areas through Assessment of Small-Scale Spatial Variability of Electrical Conductivity Data.

Authors:  Maria Isabel Senal; Anders Bjørn Møller; Triven Koganti; Bo V Iversen
Journal:  Sensors (Basel)       Date:  2022-02-15       Impact factor: 3.576

3.  Three-Dimensional Mapping of Clay and Cation Exchange Capacity of Sandy and Infertile Soil Using EM38 and Inversion Software.

Authors:  Tibet Khongnawang; Ehsan Zare; Dongxue Zhao; Pranee Srihabun; John Triantafilis
Journal:  Sensors (Basel)       Date:  2019-09-12       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.