Oxford medial unicompartmental knees display contact-loss during step-cycle motion and bicycle motion: A dynamic radiostereometric study.

Kristian Horsager1, Bart L Kaptein2, Peter B Jørgensen1, Claus F Jepsen1, Maiken Stilling1.   

Abstract

The Oxford medial unicompartmental knee is designed fully congruent, with the purpose of maintaining a large contact-area throughout motion and minimize wear. No other study has investigated this design feature in-vivo. We aimed to evaluate if contact-loss was introduced between the articulating surfaces of the Oxford medial unicompartmental knee during bicycle- and step-cycle motion, and whether this correlated with essential implant parameters, such as polyethylene (PE) wear, knee-loadings, and clinical outcome. To study contact-loss, 15 patients (12 males, mean age 69 years) with an Oxford medial unicompartmental knee (7 cemented, mean follow-up 4.4 years) were examined with use of dynamic radiostereometry (RSA) (10 frames/s). PE wear was measured from static RSA and clinical outcome was evaluated with American Knee Society Score (AKSS) and Oxford Knee Score (OKS). Data on knee-loadings were acquired from the literature. Contact-loss was deteced in all patients during both exercises, and the trend of contact-loss correlated with the knee-loadings. Median contact-loss was 0.8 mm (95%PI: 0.3; 1.5) for bicycle motion and 0.3 mm (95%PI: 0.24; 0.35) for step-cycle motion, and did not correlate with the PE wear rate of mean 0.06 mm/year. Possible in-congruency was seen in three patients. Clinical outcome scores correlated with contact-loss during step-cycle motion. In conclusion, contact-loss was seen in all patients indicating a clinical tolerance during load. Contact-loss followed the knee-loadings, which could explain why no correlation was seen with PE wear, as an increase in load was acommadated by an increase in contact-area (contact-loss reduction). The size of contact-loss may reflect clinical outcome.
© 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:357-364, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  Oxford medial unicompartmental knee arthroplasty; contact-loss; dynamic radiostereometry; knee kinematics; wear

Mesh:

Substances:

Year:  2017        PMID: 28574622     DOI: 10.1002/jor.23625

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  2 in total

1.  Similar polyethylene wear between cemented and cementless Oxford medial UKA: a 5-year follow-up randomized controlled trial on 79 patients using radiostereometry.

Authors:  Kristian Horsager; Frank Madsen; Anders Odgaard; Claus Fink Jepsen; Lone Rømer; Per Wagner Kristensen; Bart L Kaptein; Kjeld Søballe; Maiken Stilling
Journal:  Acta Orthop       Date:  2018-12-10       Impact factor: 3.717

2.  Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study.

Authors:  Peter Bo Jørgensen; Bart L Kaptein; Kjeld Søballe; Stig S Jakobsen; Maiken Stilling
Journal:  Eur Radiol Exp       Date:  2021-12-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.