| Literature DB >> 28570556 |
Abhilash Guduru1, David Fleischman2, Sunyoung Shin3,4, Donglin Zeng2, James B Baldwin2, Odette M Houghton2, Emil A Say5.
Abstract
BACKGROUND: Establish accuracy and reproducibility of subjective grading in ultra-widefield fundus autofluorescence (FAF) imaging in patients with age-related macular degeneration (AMD), and determine if an association exists between peripheral FAF abnormalities and AMD.Entities:
Mesh:
Year: 2017 PMID: 28570556 PMCID: PMC5453416 DOI: 10.1371/journal.pone.0177207
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1Examples of masked widefield image for grading.
A: Consensus agreement between both graders that the image was characterized as abnormal, with both patterns of autofluorescence (hyper- and hypo-autofluoresnce), and located in all four quadrants. B: Consensus agreement between both graders that this was a normal autofluorescence image.
Fig 2An example of a central ResMax with pattern abnormalities (hypo- and hyper-autofluorescence, both labeled).
Ultra-widefield short wavelength fundus autofluorescence in patients with age-related macular degeneration.
Patient demographics.
| Control Group, n = 11 | AMD Group, n = 28 | p-value | ||
|---|---|---|---|---|
| 64 | 80 | <0.001 | ||
| 0.713 | ||||
| Male | 3 | 11 | ||
| Female | 8 | 17 | ||
| 0.059 | ||||
| Yes | 1 | 13 | ||
| No | 9 | 15 | ||
| NA | 1 | 0 | ||
| 0.074 | ||||
| Yes | 0 | 9 | ||
| No | 9 | 17 | ||
| NA | 2 | 2 | ||
| Neovascular | 0 | 33 | not compared | |
| Non-neovascular | 0 | 23 |
*NA indicates that the information is not available.
Ultra-widefield short wavelength fundus autofluorescence in patients with age-related macular degeneration.
| Agreement in presence of any peripheral fundus autofluorescence abnormalities | ||||||||
|---|---|---|---|---|---|---|---|---|
| Grader 2 | Observed Agreement | Expected Agreement | Kappa | p-value | ||||
| Normal | Abnormal | Total | ||||||
| Grader 1 | Normal | 11 | 10 | 21 | 78.4% | 54.7% | 0.524 | <0.001 |
| Abnormal | 1 | 29 | 30 | |||||
| Total | 12 | 39 | 51 | |||||
*Cohen’s kappa, based on the frequency table of the graders’ assessments
Ultra-widefield short wavelength fundus autofluorescence in patients with age-related macular degeneration.
Inter-observer variability of peripheral autofluorescence abnormalities.
| Agreement in patterns of peripheral fundus autofluorescence abnormalities | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Grader 2 | Observed Agreement | Expected Agreement | Kappa | p-value | |||||
| HyperAF | HypoAF | Both | Total | ||||||
| Grader 1 | HyperAF | 12 | 0 | 5 | 17 | 69.0% | 39.1% | 0.49 | <0.001 |
| HypoAF | 0 | 2 | 3 | 5 | |||||
| Both | 1 | 0 | 6 | 7 | |||||
| Total | 13 | 2 | 14 | 29 | |||||
Ultra-widefield short wavelength fundus autofluorescence in patients with age-related macular degeneration.
Inter-observer agreement of peripheral autofluorescence abnormalities per quadrant.
| Grader 2 | Observed Agreement | Expected Agreement | Kappa | p-value | ||||
| Normal | Abnormal | Total | ||||||
| Grader 1 | Normal | 12 | 6 | 18 | 75.9% | 48.8% | 0.529 | 0.002 |
| Abnormal | 1 | 10 | 11 | |||||
| Total | 13 | 16 | 29 | |||||
| Grader 2 | Observed Agreement | Expected Agreement | Kappa | p-value | ||||
| Normal | Abnormal | Total | ||||||
| Grader 1 | Normal | 2 | 5 | 7 | 82.8% | 72.3% | 0.378 | 0.009 |
| Abnormal | 0 | 22 | 22 | |||||
| Total | 2 | 27 | 29 | |||||
| Grader 2 | Observed Agreement | Expected Agreement | Kappa | p-value | ||||
| Normal | Abnormal | Total | ||||||
| Grader 1 | Normal | 5 | 7 | 12 | 65.6% | 53.9% | 0.253 | 0.154 |
| Abnormal | 3 | 14 | 17 | |||||
| Total | 8 | 21 | 29 | |||||
| Grader 2 | Observed Agreement | Expected Agreement | Kappa | p-value | ||||
| Normal | Abnormal | Total | ||||||
| Grader 1 | Normal | 13 | 5 | 18 | 79.3% | 49.6% | 0.59 | <0.001 |
| Abnormal | 1 | 10 | 11 | |||||
| Total | 14 | 15 | 29 | |||||
*Cohen’s kappa, based on the frequency table of the graders’ assessments