Literature DB >> 28557311

Late Incomplete stent apposition is associated with late/very late stent thrombosis: A meta-analysis.

Ankur Sethi1, Yash Singbal2, Ujjwal Rastogi1, Vinoy S Prasad3.   

Abstract

BACKGROUND: There is a lingering controversy in the current literature about the impact of late incomplete stent apposition (LISA) on clinical outcomes, especially stent thrombosis (ST). Therefore, we aimed to synthesize the available evidence evaluating the association between LISA and adverse clinical outcomes.
METHODS: We systematically searched electronic databases for studies reporting clinical outcomes in patients with and without LISA. Relevant study characteristics and clinical outcomes were extracted. Incidence rate ratios (IRR) and 95% Confidence Interval (CI) were computed. Sensitivity analyses were done.
RESULTS: Sixteen studies with 4,946 patients; 666 patients with 20,035 patient-months follow up with LISA and 4,280 patients with 121,855 patient-months follow up without LISA were included. The estimated prevalence of LISA at follow up was 16% (95% CI 12-20%). The incidences of late/very late ST (IRR = 4.81, 95% CI 2.68-8.62) and myocardial infarction (MI) (IRR = 3.09, 95% CI 1.72-5.55) were significantly higher in the LISA group compared to patients without LISA. Subset analysis of studies reporting Academic Research Consortium definitive/probable ST (IRR = 4.98; 95% CI 2.51-9.89) and acquired LISA (IRR = 3.67, 95% CI 1.5-9.0) similarly showed increased risk of late/very late ST. The results of sensitivity analyses were consistent. There was no difference in cardiac death and target lesion revascularization.
CONCLUSION: The presence of LISA at a follow up of 6-18 months after stent implantation is associated with a higher risk of late/very late ST and MI. Additional studies are required to establish a cause and effect, and inform the management strategy.
© 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  incomplete stent apposition; myocardial infarction; stent malapposition; stent thrombosis

Mesh:

Year:  2017        PMID: 28557311     DOI: 10.1002/ccd.27102

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  3 in total

Review 1.  Coronary Stent Thrombosis- Predictors and Prevention.

Authors:  Helen Ullrich; Thomas Münzel; Tommaso Gori
Journal:  Dtsch Arztebl Int       Date:  2020-05-01       Impact factor: 5.594

2.  Filament inadequate wall apposition of the different ends of flow diverters in the abdominal aorta of rabbits.

Authors:  Kuizhong Wang; Peng Jin; Peigang Lu; Qiang Liu; Bo Li; Zhenqiang Hao
Journal:  Neuroradiol J       Date:  2019-11-27

3.  Optical coherence tomography: evaluating the effects of stent boost subtract imaging on stent underexpansion in STEMI patients.

Authors:  Yuanyuan Duan; Limin Jing; Shi Pan; Sujuan Yan; Fang Wang; Hong Yu; Beibei Zhang; Guangsheng Wei; Ming Zhang; Jiao Zhang
Journal:  BMC Cardiovasc Disord       Date:  2022-02-20       Impact factor: 2.298

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.