Literature DB >> 28557118

Effect of drink pattern and solar radiation on thermoregulation and fluid balance during exercise in chronically heat acclimatized children.

José R Rodríguez Santana1, Anita M Rivera-Brown2, Walter R Frontera2, Miguel A Rivera2, Pedro M Mayol1, Oded Bar-Or3.   

Abstract

The purposes of this study were to examine the thermoregulatory and body fluid balance responses in chronically heat acclimatized children, i.e., indigenous to a tropical climate, during exercise in four outdoor conditions and the effects of dehydration on their thermoregulatory response. Nine children (age = 13.3 ± 1.9 yr, VO2 max = 45.5 ± 9.2 ml · kg-1 · min-1 ) cycled at 60% VO2 max each under four conditions: sun exposure voluntary drinking (SuVD), sun exposure forced drinking (SuFD), shaded voluntary drinking (ShVD), and shaded forced drinking (ShFD). Exercise sessions consisted of four 20-min exercise bouts alternating with 25-min rest periods. Globe temperature and the WBGT index were higher during SuVD and SuFD compared to ShVD and ShFD (P < 0.05). The change in rectal temperature, metabolic heat production, and heat storage did not differ among the conditions. Total water intake (% IBW) was higher during SuFD (4.1 ± 0.01) and ShFD (3.7 ± 0.1) compared to SuVD (2.1 ± 0.1) and ShVD (1.0 ± 0.1) and during SuVD compared to ShVD (P < 0.05). Sweating rate (L · hr-1 ) was higher during SuFD (0.7 ± 0.1) and ShFD (0.6 ± 0.1) compared to SuVD (0.5 ± 0.1) and ShVD (0.4 ± 0.1) (P < 0.05). Total fluid loss did not differ among conditions (SuVD = 1.7 ± 0.4; SuFD = 1.5 ± 0.4; ShVD = 2.1 ± 0.2; ShFD = 1.3 ± 0.3). Results indicate that when exercising in a tropical climate, chronically heat acclimatized children demonstrate mild voluntary dehydration and adequate heat dissipation. © 1995 Wiley-Liss, Inc.
Copyright © 1995 Wiley-Liss, Inc., A Wiley Company.

Entities:  

Year:  1995        PMID: 28557118     DOI: 10.1002/ajhb.1310070512

Source DB:  PubMed          Journal:  Am J Hum Biol        ISSN: 1042-0533            Impact factor:   1.937


  3 in total

1.  Voluntary fluid intake and core temperature responses in adolescent tennis players: sports beverage versus water.

Authors:  M F Bergeron; J L Waller; E L Marinik
Journal:  Br J Sports Med       Date:  2006-05       Impact factor: 13.800

2.  Voluntary drinking and hydration in trained, heat-acclimatized girls exercising in a hot and humid climate.

Authors:  Anita M Rivera-Brown; Farah A Ramírez-Marrero; Boguslaw Wilk; Oded Bar-Or
Journal:  Eur J Appl Physiol       Date:  2008-02-05       Impact factor: 3.078

3.  Voluntary drinking and hydration in non-acclimatized girls exercising in the heat.

Authors:  Boguslaw Wilk; Anita M Rivera-Brown; Oded Bar-Or
Journal:  Eur J Appl Physiol       Date:  2007-09-05       Impact factor: 3.078

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.