Literature DB >> 28555592

Repositionable percutaneous aortic valve implantation with the LOTUS valve: 30-day and 1-year outcomes in 250 high-risk surgical patients.

Ian T Meredith1, Nicolas Dumonteil, Daniel J Blackman, Didier Tchétché, Darren L Walters, David Hildick-Smith, Ganesh Manoharan, Jan Harnek, Stephen G Worthley, Gilles Rioufol, Thierry Lefèvre, Thomas Modine, Nicolas M Van Mieghem, Ted Feldman, Dominic J Allocco, Keith D Dawkins.   

Abstract

AIMS: The REPRISE IIE trial aimed to evaluate outcomes following transcatheter aortic valve implantation of the fully repositionable and retrievable LOTUS valve with a unique seal designed to minimise paravalvular leak (PVL). METHODS AND
RESULTS: This prospective, multicentre study enrolled 250 patients with severe aortic stenosis considered high-risk for surgery by a multidisciplinary Heart Team. An independent clinical events committee adjudicated events per Valve Academic Research Consortium criteria. Mean age was 84 years; 77% were in NYHA Class III/IV. LOTUS valve implantation produced significant haemodynamic improvements at one year without valve embolisation, ectopic valve deployment, or additional valve implantation. Primary endpoints were met as the 30-day mortality rate in the extended cohort (4.4%, N=250), and mean valve gradient in the main cohort (11.5±5.2 mmHg, N=120) were below (p<0.001) their predefined performance objectives. At 30 days, disabling stroke was 2.8% and new pacemaker implantation was 28.9% in all patients and 32.0% in pacemaker-naïve patients. By one year, all-cause mortality was 11.6%, disabling stroke was 3.6%, 95% of patients alive were in NYHA Class I/II, and there was no core laboratory-adjudicated moderate/severe PVL.
CONCLUSIONS: LOTUS valve implantation produced good valve haemodynamics, minimal PVL, sustained significant improvement in functional status, and good clinical outcomes one year post implant.

Entities:  

Mesh:

Year:  2017        PMID: 28555592     DOI: 10.4244/EIJ-D-16-01024

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  4 in total

1.  Outcomes with a latest generation self-expandable, intra-annular, re-sheathable transcatheter heart valve system: analysis of patients with impaired left ventricular function and determinants for pacemaker implantation.

Authors:  Andreas Schaefer; Niklas Neumann; Matthias Linder; Niklas Schofer; Yvonne Schneeberger; Florian Deuschl; Gerhard Schoen; Stefan Blankenberg; Hermann Reichenspurner; Lenard Conradi; Ulrich Schäfer
Journal:  Clin Res Cardiol       Date:  2018-04-28       Impact factor: 5.460

Review 2.  How to Image and Manage Prosthesis-Related Complications After Transcatheter Aortic Valve Replacement.

Authors:  Nina C Wunderlich; Jörg Honold; Martin J Swaans; Robert J Siegel
Journal:  Curr Cardiol Rep       Date:  2021-07-01       Impact factor: 2.931

3.  Transcatheter aortic valve implantation with the repositionable and fully retrievable Lotus Valve SystemTM.

Authors:  Rodrigo Bagur; Tawfiq Choudhury; Mamas A Mamas
Journal:  J Thorac Dis       Date:  2017-09       Impact factor: 2.895

Review 4.  TAVI and Post Procedural Cardiac Conduction Abnormalities.

Authors:  Antonio Mangieri; Claudio Montalto; Matteo Pagnesi; Giuseppe Lanzillo; Ozan Demir; Luca Testa; Antonio Colombo; Azeem Latib
Journal:  Front Cardiovasc Med       Date:  2018-07-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.