Literature DB >> 28555206

A comparison of two implants with conical vs internal hex connections: 1-year post-loading results from a multicentre, randomised controlled trial.

Maurizio Cannata, Tommaso Grandi, Rawad Samarani, Luigi Svezia, Giovanni Grandi.   

Abstract

PURPOSE: To compare the clinical and radiological outcomes of identical implants with conical or internal hex connections.
METHODS: A total of 90 patients with partial edentulism requiring one implant-supported prosthesis were randomly allocated in two equal groups (n = 45) to receive either implants with a conical connection or implants of the same type, but with an internal hex connection at three centres. Patients were followed for 1 year after loading. Outcome measures were implant failures, any complication and marginal bone level changes.
RESULTS: One patient (2.2%) belonging to the internal hex group dropped out. One implant (2.2%) failed in the conical group. There were no statistically significant differences in implant failures between the two groups (2.2% vs. 0%, difference 2.2; 95% CI: -1.3; 5.7; P = 0.315). Two complications occurred in the conical group and two in the internal hex group (P = 1.000, difference 0.00, 95% CI: -3.1; 3.1). The 12-month peri-implant bone resorption was similar in both groups: 0.56 ± 0.53 mm (95% CI 0.03; 1.09) in the conical group and 0.60 ± 0.62 mm (95% CI 0.02; 1.22) in the internal hex group (difference = 0.04 ± 0.55, 95% CI: -0.51; 0.59, P = 0.745).
CONCLUSIONS: Within the limitation of this study, preliminary short-term data (1 year post-loading) did not show any statistical differences between the two internal connection types, therefore clinicians could choose whichever connection they prefer. Conflict of interest statement: Tommaso Grandi serves as consultant for J Dental Care, Modena, Italy. This study was completely self-financed and no funding was sought or obtained, not even in the form of free materials.

Entities:  

Mesh:

Year:  2017        PMID: 28555206

Source DB:  PubMed          Journal:  Eur J Oral Implantol        ISSN: 1756-2406            Impact factor:   3.123


  6 in total

1.  Short Dental Implants (6 mm) Versus Standard Dental Implants (10 mm) Supporting Single Crowns in the Posterior Maxilla and/or Mandible: 2-Year Results from a Prospective Cohort Comparative Trial.

Authors:  Luigi Svezia; Filippo Casotto
Journal:  J Oral Maxillofac Res       Date:  2018-09-30

2.  Bacterial Microleakage at the Implant-Abutment Interface: An In Vitro Study.

Authors:  Simonetta D'Ercole; Tatiane Cristina Dotta; Marzieh Ramezani Farani; Niloofar Etemadi; Giovanna Iezzi; Luca Comuzzi; Adriano Piattelli; Morena Petrini
Journal:  Bioengineering (Basel)       Date:  2022-06-26

3.  A Comparative Evaluation of the Strain Transmitted through Prostheses on Implants with Two Different Macro-Structures and Connection during Insertion and Loading Phase: An In Vitro Study.

Authors:  Riyam Kassem; Amar Samara; Ameer Biadsee; Shchada Masarwa; Tarek Mtanis; Zeev Ormianer
Journal:  Materials (Basel)       Date:  2022-07-16       Impact factor: 3.748

4.  The compressive strength of implant-abutment complex with different connection designs.

Authors:  Hsien-Ching Hung; Chiung-Shing Huang; Yu-Hwa Pan
Journal:  J Dent Sci       Date:  2019-03-28       Impact factor: 2.080

5.  Effects of Aging Torque Controllers on Screw Tightening Force and Bacterial Micro-Leakage on the Implant-Abutment Complex.

Authors:  Yousef Jiries; Tamar Brosh; Shlomo Matalon; Vladimir Perlis; Zeev Ormianer
Journal:  Materials (Basel)       Date:  2022-01-14       Impact factor: 3.623

Review 6.  Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis.

Authors:  Adam Ibrahim; Bruno Ramos Chrcanovic
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.